1.Select the UTILITY option on the toolbar and press Enter.

2.Select either the QUICK ERASE or FULL ERASE HARD DISK option and follow the instructions.

Iomega Zip drive test

Use the Iomega Zip Drive Test to test the Zip drive and the drive interface. The test takes about 20 seconds to run.

The default tests the following:

vController

vMax Seek (50 times)

vRandom Seek (300 sectors)

Asset EEPROM backup

When replacing a system board, this utility allows the backup of all Asset information from the EEPROM to diskette. This utility also restores data to the EEPROM from diskette after replacement of the system board.

To run this utility, use the following procedure.

vSelect Utility

vSelect Asset EEPROM Backup

vFollow instructions on screen.

Viewing the test log

Errors reported by the diagnostic test will be displayed by the program as a failed test.

To view details of a failure or to view a list of test results, use the following procedure from any test category screen.

vPress F3 to activate the log file.

vPress F3 again to save the file to diskette or F2 to print the file.

SIMM/DIMM/RIMM memory errors

SIMM/DIMM/RIMM error messages issued by the IBM PC Enhanced

Diagnostics.

Message

Failure Found

Recommended Actions

 

 

 

2xx-1y

A memory error was detected in

Replace the SIMM in the socket

 

SIMM socket Y.

identified by the last digit of the

 

 

error code.

 

 

Re-run the test.

 

 

If the same error code occurs

 

 

again, replace the system board.

 

 

 

40Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Page 54
Image 54
IBM 6578, 6579, 6269, 6059 Iomega Zip drive test, Asset Eeprom backup, Viewing the test log, SIMM/DIMM/RIMM memory errors