POST Error Code

FRU/Action

 

 

 

214XX

1.

WORM Drive

 

 

 

 

215XXXC, 215XXXD, 215XXXE, 215XXXUIf an

1.

CD-ROM Drive I

external device, and power-on LED is off, check

2.

CD-ROM Drive II

external voltages

 

Enhanced CD-ROM Drive II

 

 

 

 

Any CD-ROM Drive

 

3.

SCSI Cable

 

4.

SCSI Adapter or System Board

 

 

 

216XX

1.

Scanner

 

 

 

 

217XXIf an external device, and power-on LED is

1.

Rewritable Optical Drive

off, check external voltages

2.

SCSI Adapter or System Board

 

 

3.

SCSI Cable

 

 

 

218XXCheck for multi CD tray or jukebox

1.

Changer

 

 

 

 

219XX

1.

SCSI Communications Device

 

 

 

 

24201Y0, 24210Y0Be sure wrap plug is attached

1.

ISDN/2 Adapter

 

 

2.

ISDN/2 Wrap Plug

 

3.

ISDN/2 Communications Cable

 

 

 

273XX

1.

1 Mbps Micro Channel

 

 

2.

Infrared LAN Adapter

 

 

 

27501, 27503, 27506, 27507

1.

ServerGuard Adapter

 

 

2.

System Board

 

3.

Riser card

 

 

 

27502, 27504, 27510, 27511, 27533, 27534, 27536,

1.

ServerGuard Adapter

27537

 

 

 

 

 

27509

1.

Remove redundant adapters, run Auto

 

 

 

Configuration program, then retest.

 

 

 

27512

1.

WMSELF.DGS diagnostics file is missing

 

 

2.

WMSELF.DGS diagnostics file is incorrect

 

 

 

27535

1.

3V Lithium Backup Battery

 

 

2.

ServerGuard Adapter

 

 

 

27554

1.

Internal Temperature out of range

 

 

2.

ServerGuard Adapter

 

 

 

27555, 27556

1.

ServerGuard Adapter

 

 

2.

Power Supply

 

 

 

86Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,

6649

Page 100
Image 100