Diagnostic Error Code

FRU/Action

 

 

 

086-198-XXXMouse Port interface test aborted

1.

If a component is called out, make sure it is

 

 

 

connected and/or enabled

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problemssection

 

 

 

086-199-XXXMouse Port interface test failed,

1.

Go to the Undetermined problemssection

cause unknown

2.

Flash the system and re-test

 

 

3.

Replace component under function test

 

 

 

089-000-XXXMicroprocessor Test Passed

1.

No action

 

 

 

 

089-XXX-XXXMicroprocessor failure

1.

Microprocessor(s)

 

 

2.

System board

 

 

 

089-195-XXXMicroprocessor Test aborted by

1.

Information

user

2.

Re-start the test, if necessary

 

 

 

 

089-196-XXXMicroprocessor test halt, error

1.

Press F3 to review the log file

threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 

089-197-XXXMicroprocessor test warning

1.

Make sure the component that is called out is

 

 

 

connected and/or enabled

 

2.

Re-run test

 

3.

Component that is called out in warning statement

 

4.

Component under test

 

 

 

089-198-XXXMicroprocessor test aborted

1.

Flash the system and re-test

 

 

2.

Go to the Undetermined problemssection

 

 

 

089-199-XXXMicroprocessor test failed, cause

1.

If a component is called out, make sure it is

unknown

 

connected and/or enabled

 

 

 

2.

Go to the Undetermined problemssection

 

3.

Flash the system and re-test

 

4.

Replace component under function test

 

 

 

170-000-XXXVoltage Sensor(s) Test Passed

1.

No action

 

 

 

 

170-0XX-XXXVoltage Sensor(s) failure

1.

Flash system

 

 

2.

System board

 

 

 

170-195-XXXVoltage Sensor(s) Test aborted by

1.

Information

user

2.

Re-start the test, if necessary

 

 

 

 

170-196-XXXVoltage Sensor(s) test halt, error

1.

Press F3 to review the log file

threshold exceeded

2.

Re-start the test to reset the log file

 

 

 

 