IBM 6648, 6569, 6568, 6649 manual Types 6058/6059/6269/6578/6579

Models: 6568 6649 6058 6269 6569 6578 6059 6579 6648

1 248
Download 248 pages 20.59 Kb
Page 169
Image 169

POST Error Code

FRU/Action

 

 

 

175

1.

Run Configuration. See “Setup Utility

 

 

 

program” on page 122.

 

2.

System Board

 

 

 

176

1.

Covers were removed from the computer

 

 

 

 

177Corrupted Administrator Password

1.

System Board

 

 

 

 

178

1.

System Board

 

 

 

 

183

1.

Enter the administrator password

 

 

 

 

184No RFID Antenna

1.

Make sure Asset Care and Asset ID are

 

 

 

enabled in Configuration/Setup

 

2.

RFID Antenna

 

3.

System Board

 

 

 

185Corrupted boot sequence

1.

Set configuration and reinstall the boot

 

 

 

sequence

 

 

 

186

1.

System Board

 

 

 

 

187

1.

Clear Administration password

 

 

2.

System Board

 

 

 

189

1.

More than three password attempts were

 

 

 

made to access the computer

 

 

 

190Chassis intrusion detector was cleared. This is

1.

System Board

information only, no action required. If this code

 

 

does not clear:

 

 

 

 

 

1XXNot listed above

1.

System Board

 

 

 

 

201, 20XMemory data error

1.

Run Enhanced Diagnostics Memory Test

 

 

2.

Memory Module

 

3.

System Board

 

 

 

225

1.

Unsupported Memory

 

 

 

 

229External cache test error

1.

L2 Cache Memory

 

 

2.

System Board

 

 

 

262POST detected a base memory or extended

1.

Run Setup. Check System Summary menu for

memory type error

 

memory. (See “Setup Utility program” on

 

 

 

 

page 122.)

 

2.

Run the Extended Memory Diagnostic tests.

 

 

 

Chapter 3. Types 6058/6059/6269/6578/6579 155

Page 169
Image 169
IBM 6648, 6569, 6568, 6649 manual Types 6058/6059/6269/6578/6579