Diagnostic Error Code FRU/Action
025-197-XXXIDE interface test warning 1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
025-198-XXXIDE interface test aborted 1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problemssection
025-199-XXXIDE interface test failed, cause
unknown 1. Go to the Undetermined problemssection
2. Flash the system and re-test
3. Replace component under function test
030-000-XXXSCSI interface TestPassed 1. No action
030-00X-XXX
030-01X-XXXSCSI interface failure 1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-027-XXXSCSI interface
Configuration/Setup error 1. SCSI signal cable
2. Flash the system
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-03X-XXX
030-04X-XXXSCSI interface error 1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. installed System board
030-195-XXXSCSI interface Testaborted by
user 1. Information
2. Re-start the test, if necessary
030-196-XXXSCSI interface test halt, error
threshold exceeded 1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter1. IBM PC Enhanced Diagnostics error codes 13