Please go through this section with the installation engineer so that you fully understand all the basic operating and maintenance procedures for your stove.

The engineer will be happy to answer your questions and give you any help you may need.

General Notes

This stove is not for use with any solid fuels. It is only suitable for Natural (mains) Gas or LPG (Liquified Petroleum Gas) when the correct burner is fitted.

Please remember that when the stove is alight it is very hot.

EXCEPT FOR THE CONTROLS NEVER TOUCH THE STOVE WITH YOUR BARE HANDS WHILST IT IS HOT.

The stove must not be touched when it is in operation. However, if you do need to do so after it has been turned off and before it has completely cooled down (usually after about one hour) please make sure that you wear stout oven gloves.

Flue Spillage Safety Monitoring Device

A Safety Cut-Off System.

All stoves are fitted with an Oxygen Depletion Sensitive Pilot so that should the flue and/or chimney become blocked at any time, the stove will automatically cut off.

Normally the pilot can be re-ignited after waiting about five minutes for the sensor to cool down, but in the event of the system tripping, have the flue and chimney checked by your installation engineer.

Lighting and controlling the stove.

Remember that the stove is designed to be operated with the door and spinwheel securely closed.

1.Near the stove will be the gas isolation tap. Turn this to the on position.

2.Between the front and rear legs on the right hand side of the stove you will find the burner control knob, as shown in Fig. 1.

a. Switching On/ Ignition.

Depress the control knob and turn counter clockwise. Gas will flow to the pilot burner, the piezo igniter will give off a high voltage spark & the pilot burner will light. (More than one attempt may have to be made on first lighting the fire.) Keep the control knob depressed for approximately

10 seconds to heat up the thermocouple, Turn the control knob fully counter clockwise to release gas to the main burner.

b. Control of Gas Flow.

Turning the control knob clockwise reduces the gas rate from the maximum to the pre-set minimum setting. Turning between maximum & minimum does not actuate the piezo igniter. The control valve can only be set on pilot by depressing the knob & turning it to the pre selected pilot position.

Control Knob

Fig. 1. Gas Controls

c. Switching Off When in Pilot Position.

Press control knob and turn clockwise to off.

IMPORTANT

Interruption of Gas Supply.