General Troubleshooting

Symptom

 

Possible Cause

 

Possible Action

 

Excessive load on the circuit

Make sure that the total load

Circuit breaker

 

 

 

does not exceed 80% of the

 

 

 

breaker or fuse nominal current

or fuse keeps

 

 

 

blowing

Short circuit along the power

Check the power lines and

 

 

 

lines

 

power cords

 

 

 

 

 

 

No energy on power outlet

Check power outlet

 

 

 

Change to another outlet

 

 

 

 

 

Product does not

Loose or damaged power cord

Check the power cord

power up

Blown fuse

Replace blown fuse with a good

 

 

 

 

 

one of the same type and rating

 

 

 

 

 

 

Internal problem

Send product for repair

 

 

 

 

 

 

Wrong starting address on the

Set the correct starting address

 

 

fixture

 

on the fixture

 

 

 

Use the right fader(s) on the

 

 

 

 

controller

 

Wrong DMX personality on the

Set the correct DMX fixture’s

Fixture does not

 

fixture

 

personality

 

 

Assign the faders accordingly

respond to DMX

 

 

 

 

 

 

 

Wrong polarity setting on the

Change the signal polarity on

 

 

DMX controller

 

the controller

 

 

 

 

 

 

Loose or damaged DMX cable

Check the DMX cable before

 

 

 

 

the faulty unit

 

 

 

 

 

 

Internal problem

Send product for repair

 

 

 

 

 

 

Signal cables are not DMX

Replace non DMX cables with

 

 

compatible

 

true DMX cables

 

 

 

 

 

 

Interference with AC or radio

Keep DMX cables away from

 

 

signals

 

AC wires or radio equipment

Intermittent DMX

DMX cable too long

Install an optically coupled DMX

 

 

 

amplifier right before the fixture

Problems

 

 

 

 

 

 

with intermittent problems

 

 

 

 

 

 

 

 

 

 

Too many fixtures connected

Install an optically coupled DMX

 

 

 

 

amplifier after unit #32

 

Terminator not connected

Install a terminator, as indicated

 

 

 

 

in the “DMX Primer” section.

 

 

 

 

 

If you still experience problems after trying the above solutions, contact

CHAUVET® Technical Support.