EXTENSION CORDS

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. (See Figure C, next page.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Figure C.)

4.When using more than one extension cord to make up the total length, make sure each cord con- tains at least the minimum wire size required. (See Figure C.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Figure C.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.

Recommended Mimimum Wire Gauge for 120 Volt Extension Cords*

Nameplate

 

 

 

 

 

 

 

 

 

Amperes (At

 

 

 

Extension Cord Length

 

 

 

Full Load)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 Feet

 

50 Feet

75 Feet

100 Feet

 

150 Feet

0 - 2.0

18

 

18

18

18

 

16

2.1

- 3.4

18

 

18

18

16

 

14

3.5

- 5.0

18

 

18

16

14

 

12

6.1

- 7.0

18

 

16

14

12

 

12

7.1 - 12.0

16

 

14

12

10

 

 

X

12.1

- 16.0

14

 

12

10

X

 

X

16.1

- 20.0

12

 

10

X

X

 

X

SYMBOLOGY

 

Double Insulated

 

 

 

Canadian Standards Association

 

 

 

Underwriters Laboratories, Inc.

 

 

V ~

Volts Alternating Current

A

Amperes

no load xxxx per min.

No Load Revolutions per Minute

 

 

SKU 44677

For technical questions, please call 1-800-444-3353.

Page 7

Page 7
Image 7
Chicago Electric 44677 operating instructions Extension Cords