OPERATING

REAR HEX JAM

LEVER (#5)

CAP SCREW

NUT (#10)

FRONT HEXT JAM

(#3)

 

NUT (#10)

 

UPPER TONG

(#46)

 

HEX NUT (#20)

TONG

 

TIP

 

(#48)

FIGURE F

LOWER TONG (#47)

To Use The Power Switch:

1.The Power Switch (part #25) allows electrical current to the Spot Welder to be turned “ON” and “OFF”. (See Figure D, and Assy. Diagram.)

2.Turn the Power Switch (part #25) sideways in either direction to start the electrical current. Release the Power Switch to stop the electrical current.

To Use The Operating Lever:

1.Caution: Never touch the Upper and Lower Tongs (parts #46, #47) when welding a workpiece. Allow the Tong Tips (part #48) and the workpiece to cool before handling. (See Figures A, B, E, and Assy. Diagram.)

2.The Operating Lever (part #5) allows you to open and close the Upper and Lower Tongs (parts #46, #47). (See Figures A, F, and Assy. Diagram.)

3.Close the Operating Lever (part #5) during the welding process to compress the workpieces between the Tong Tips (part #48). Open the Operating Lever after the spark appears and each weld is made to release the workpieces. (See Figures B,

A, F, and Assy. Diagram.)