| OPERATING | |
REAR HEX JAM | LEVER (#5) | |
CAP SCREW | ||
NUT (#10) | ||
FRONT HEXT JAM | (#3) | |
| ||
NUT (#10) |
|
UPPER TONG
(#46)
| HEX NUT (#20) |
TONG |
|
TIP |
|
(#48) | FIGURE F |
LOWER TONG (#47) |
To Use The Power Switch:
1.The Power Switch (part #25) allows electrical current to the Spot Welder to be turned “ON” and “OFF”. (See Figure D, and Assy. Diagram.)
2.Turn the Power Switch (part #25) sideways in either direction to start the electrical current. Release the Power Switch to stop the electrical current.
To Use The Operating Lever:
1.Caution: Never touch the Upper and Lower Tongs (parts #46, #47) when welding a workpiece. Allow the Tong Tips (part #48) and the workpiece to cool before handling. (See Figures A, B, E, and Assy. Diagram.)
2.The Operating Lever (part #5) allows you to open and close the Upper and Lower Tongs (parts #46, #47). (See Figures A, F, and Assy. Diagram.)
3.Close the Operating Lever (part #5) during the welding process to compress the workpieces between the Tong Tips (part #48). Open the Operating Lever after the spark appears and each weld is made to release the workpieces. (See Figures B,
A, F, and Assy. Diagram.)
SKU 45690 | PAGE 9 |