To Change The Bit:

1.Pull forward on the Depth Collar (2) and remove it from the Clutch Housing (5).

(See Figure A.)

2.Pull the Bit (3) straight out with pliers if it is difficult to remove. (See Figure A.)

3.Push the new Bit (3) into the Bit Tip Holder (4) until the shank of the Bit snaps in place. (See Figure A.)

4.Replace the Depth Collar (2) onto the Clutch Housing (5). Align the ribs on the inside of the Depth Collar with the grooves on the outside of the Clutch Housing before snapping the Depth Collar in place. (See Figure A.)

OPERATING INSTRUCTIONS

1.To start the Drywall Screwdriver, depress the Trigger (38). To stop the tool, release the Trigger. The variable speed Trigger permits speed control. The farther the Trigger is depressed, the higher the speed of the Tool. (See Figure B.)

2.To lock the Trigger (38) in the “ON” position for continuous operation, depress the Trigger and push in on the

Trigger Lock (39). The tool will continue to run. To turn off the tool, squeeze and release the Trigger once. Prior to using the Drywall Screwdriver (each time),

make sure the Trigger Lock mechanism is working properly. Always release the Trigger Lock mechanism before disconnecting the Drywall Screwdriver from its electrical outlet. Failure to do so will cause the tool to start immediately the next time it is plugged in, resulting in possible injury or property damage.

(See Figure B.)

3.The Drywall Screwdriver also features a Forward/Reverse Switch. The Forward/ Reverse Switch is used to reverse

the rotation of the Bit for backing out screws. To reverse the rotation, turn off the Drywall Screwdriver and push the Forward/Reverse Switch to the right (when viewed from the back of the tool). To position the Forward/Reverse Switch for forward operation, turn off the tool and push the Forward/Reverse Switch to the left. (See Figure B.)

4.The Depth Collar (part #2) allows the operator to increase or decrease the fastening depth. To seat a screw deeper in a workpiece, turn the Depth Collar to the right. To seat a screw higher in a workpiece, turn the Depth Collar to the left. (See Figures A and B.)

 

DEPTH

FORWARD/REVERSE

 

 

 

 

COLLAR

 

TRIGGER

 

 

(2)

SWITCH

 

LOCK (39)

 

 

 

TRIGGER

 

 

 

 

 

(38)

 

 

 

FIGURE B

 

 

 

 

 

 

 

 

 

SKU 9624

For technical questions, please call 1-800-444-3353.