Chicago Electric 98265 Maintenance Servicing, Cleaning, Maintenance, Lubrication

Models: 98265

1 21
Download 21 pages 1.38 Kb
Page 14
Image 14
REV 10b

MAINTENANCE AND

SERVICING

Procedures not specifically explained in this manual must be performed only by a qualified technician.

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL

OPERATION:

Turn the Power Switch of the tool to its “OFF” position and unplug the tool from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.

TO PREVENT SERIOUS INJURY FROM TOOL FAILURE:

Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.

Cleaning, Maintenance, and

Lubrication

1.BEFORE EACH USE, inspect the gen- eral condition of the tool. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, damaged electrical wiring, loose or worn out blade, and any other condition that may affect its safe operation.

2.AFTER USE, clean external surfaces of the tool with clean cloth. Drain water from the water tray and wash out any residue from the sump pump.

3.Tool service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.

4.When servicing a tool, use only identical replacement parts. Follow instructions in the “Inspection,

Maintenance, And Cleaning” section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury.

5.WARNING! If the supply cord of this power tool is damaged, it must be replaced only by a qualified service technician.

Changing the Blade

1.Disconnect the power supply. Have the Tile Saw in front of you so that you are facing the saw blade and the clear plas- tic Cover (A27)

2.The blade assembly must be at the open end of the water tray to the right of where the Worktables end (D06).

Fig. 5

3.Remove the three Hex Screws (A28) holding the clear Cover to the Blade Cover. (See Fig. 5.)

4.Put the flat wrench over the blade’s larger Hex Bolt (A32) to keep the blade from turning. Use a hex T-wrench (not included) to remove the blade’s retaining hex bolt by turning the bolt counterclock- wise.