Chicago Electric 98391 Checking and Filling Fuel, WARNING! To prevent serious injury from fire

Models: 98391

1 42
Download 42 pages 36.12 Kb
Page 11
Image 11
WARNING! To prevent serious injury from fire:

5.Wipe off any spilled oil.

CAUTION! Do not run the engine with too little or too much oil. The engine will be permanently damaged.

Checking and Filling Fuel

1.Check the fuel level on the built-in fuel gauge.

How to Shut Engine OffWARNING! To prevent serious injury from fire:

Fill the fuel tank in a well-venti- lated area away from ignition sourc- es. Do not smoke.

2.To fill the Fuel Tank, first wipe off the

Fuel Tank Cap and the surrounding area.

3.Unscrew, and remove the Fuel Tank Cap.

4.Fill the Fuel Tank to about 1 inch under the fill neck of the tank with #2 diesel.

5.Then replace the Fuel Tank Cap.

Bleed the fuel line

This is a two man operation. Place rags under the bleeding points to catch flow of fuel.

1.The fuel system should be bled to remove possible trapped air from the system before first use and after each fuel filter, fuel tank flushing, or general service of the diesel generator. Note: Place rags at the bleeding points to capture spilled fuel.

2.Turn the fuel valve to the off position. Top off fuel tank with fresh diesel fuel. Slide the hose clamp away from the fuel pump end. Loosen the hose at the pump to allow fuel to bleed

out. Turn the fuel valve to its open position. Depress the decompression lever and while holding it down crank the engine for a few seconds at a time. Fuel and trapped air will emerge from the line and as soon as just fuel flows without traces of air, push the fuel line back onto the intake of the pump and stop cranking the engine. Reattach the hose clamp. Note: Never crank the engine more than ten seconds at a time. Allow at least one minute prior to further cranking.

3.Using two wrenches, hold the injector with one and back off the steel feed line nut with the other wrench. Repeat the above mentioned flushing cycle to bleed the air from the injector. Wipe all spilled fuel from the engine and components. Note: Do not close the fuel valve with the engine running. This may only be done for the intention of shutting the engine off should the fuel shut-off system fail.

Connect the Battery

1.The Generator ships with the nega- tive battery cable disconnected. Before the generator can be started the covering on the battery cable must be removed and the cable must be secured to the negative ground terminal on the battery. Recheck bat- tery’s positive terminal connection for tightness.

How to Shut Engine Off

A diesel engine is not operated like a gasoline engine. When operating a diesel engine, one should be aware of various options of how to shut the engine off.

SKU 98391

For technical questions, please call 1-800-444-3353.

Page 11

Page 11
Image 11
Chicago Electric 98391 manual Checking and Filling Fuel, WARNING! To prevent serious injury from fire, Bleed the fuel line