Chicago Electric 98391 manual Operating Instructions, Grounding, Starting the Engine

Models: 98391

1 42
Download 42 pages 36.12 Kb
Page 10
Image 10
Grounding

3.Install the Generator on a concrete slab or other area where water can not reach it.

4.Generator placement should allow four feet of access on all sides for maintenance­.

5.Place the Generator as close as pos- sible to the electrical tools and equip- ment being­ powered to reduce the length of extension cords.

Grounding

1.Connect a #12 AWG grounding wire (not included) from the Grounding Point on the Generator to a ground- ing rod (not included) that has been driven at least 24 inches into the ground. The grounding rod must be a copper or brass rod which can ad- equately ground the Generator. Only a trained and licensed electrician should perform this procedure.

Grounding Point

2.Electrical and other permits may be required for the installation of emer- gency power systems. Investigate local building and electrical codes before installing this unit. Installa- tion must be completed by a licensed contractor.

Operating Instructions

Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Starting the Engine

Inspect engine and equipment looking for damaged, loose, leaking and missing parts before set up and starting. If any problems are found, do not use equipment until fixed properly.

Checking and Filling Engine Oil

CAUTION! Your Warranty is VOID if the engine’s crankcase is not properly filled with oil before each use. Before each use, check the oil level. Do not run the engine with low or no engine oil. Running the engine with no or low engine oil WILL permanently damage the engine.

1.Open the front panel; remove the dip- stick and wipe it off with a clean rag.

2.Reinsert the dipstick completely and remove it to check the oil level. The oil level should be between the high and low marks on the dipstick.

3.If the oil level is below the low mark on the dipstick add the appropriate type of oil until the oil level is between the high and the low marks.

Oil type: SAE 5W-40

4.Replace the Oil Dipstick.

SKU 98391

For technical questions, please call 1-800-444-3353.