Assembly And Installation

Installation Instructions

 

 

 

 

LCD2C

Assembly And Installation

 

 

 

 

For RPA Models Only

 

 

 

 

 

WARNING: Failure to provide adequate structural strength

 

 

 

for this component can result in serious personal injury or

6

 

 

damage to equipment! It is the installer’s responsibility to

 

 

 

make sure the structure to which this component is attached

(G) x 4

 

 

can support five times the combined weight of all equipment.

 

 

 

Reinforce the structure as required before installing the

 

 

 

component.

 

 

 

(J) x 4

7

(I) x 2

1. Mark the six mounting hole locations through the ceiling

 

 

 

plate. (See Figure 1)

 

RPA

 

 

2. Drill six 7/32" holes.

 

 

 

A

 

 

 

 

 

 

 

3. Use six fasteners (not provided) to mount the ceiling plate

 

 

 

to the appropriate structural ceiling. The 1-1/2" NPT pipe

 

 

 

must be pointing down. (See Figure 1)

 

 

 

 

 

 

 

 

(H) x 4

8

E

1

X6

2

X6

 

 

 

 

 

 

 

 

 

 

Figure 2

 

 

 

 

7. Slide both projector arms (A) onto the 1-1/2" vertical pipe

 

 

 

 

section and secure using two 5/16-18 x 3/8" set screws (I)

 

 

 

 

on each arm.

 

 

 

 

 

8.

Thread 1-1/2" safety nut (E) onto threaded end of the 1-1/2"

 

 

 

 

pipe section.

 

 

 

 

 

9.

Mount projector hanging bracket to your projector (see RPA

 

 

 

 

instructions).

 

 

3

 

 

10. Partially thread 10-24 thumbscrews onto 10-24 studs at top

X6

 

 

of hanger bracket plate. The quantity of thumbscrews may

 

 

 

 

vary from three to six.

 

 

Figure 1

4.Thread the 1-1/2" NPT pipe (C) into the ceiling plate and tighten securely.

WARNING: Installations using a column longer than 24 inches require the use of a CMA340 Support Cable

11.Align studs with key slots of RPA, slide RPA into place, and secure RPA by tightening thumbscrews.

12.Adjust projector for correct registration.

For RPM Models Only

1.Proceed with Steps 1-5 under For RPA Models Only.

2.Place RPM on its top so that four screw holes are visible through the square in the RPM base. (See Figure 3)

accessory.

5.Secure NPT pipe to ceiling plate using one 5/16-18x3/8" set screw (I).

6.Attach RPA to projector arm (A) using four 1/4-20 X 1-1/2" carriage bolts (H), four 1/4-20 acorn nuts (G) and 1/4" flat washers (J). (See Figure 2)

3.Insert four 1/4"-20x1-1/2" (L) button head cap screws into the bottom of the RPM. (See Figure 3)

NOTE: The RPM base is not shown in Figure 3 for clarity only. It should NOT be removed for this installation process.