| INSTALLATION |
|
| |||
|
|
|
|
|
|
|
|
|
|
TECHNICAL SPECIFICATIONS - POWER WAVE 355M |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| INPUT AC VOLTAGE & DC OUTPUT |
|
| ||
| Product | Ordering | Input AC | Rated DC Output | Output | Weight | Dimensions |
| |
| Name | Information | Voltage | Amps/Volts/Duty Cycle | Range | with Cord | HxWxD |
| |
|
|
|
|
|
| (continuous) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 200 | 350A / 34V / 60% |
|
| 14.8” x 13.3” x |
|
| POWER |
|
|
| 27.8”* |
| |||
| WAVE |
|
| AMPS | (81.5 lbs.) | (373 x 338 x |
| ||
| 355M |
|
| (37.0 kg.) | 706*)mm |
| |||
|
|
|
| 575 | 300A / 32V /100% |
|
|
|
|
|
|
|
| 50/60 Hz | 1& 3 Phase |
|
| * Includes Handles |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
*Overall Length Including Handle, 21.6” (549mm) without handle. Insulation Class 180 (H)
POWER WAVE 355M INPUT CURRENT
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz | Output | Recommended |
|
|
| |||
|
|
|
|
|
|
|
|
|
Voltage | Phases | 300Amps @ | 350Amps @ | Line Cord | Fuse size | Notes | ||
|
| 32Volts(100%) | 34Volts(60%) | AWG |
|
|
|
|
200 | 1 | Not | Not |
| Note 1 |
|
| |
|
| Recommended | Recommended |
|
|
|
|
|
208 | 1 | 76 | 94 | 2 | 125A | Note 2 | ||
230 | 1 | 69 | 85 | 4 | 125A | Note 2 | ||
380 | 1 | Not | Not |
| Note 1 | |||
|
| Recommended | Recommended |
|
|
|
|
|
400 | 1 | Not | Not | Note 1 |
| |||
|
| Recommended | Recommended |
|
|
|
|
|
415 | 1 | 41 | 64 | 6 | 80A | Note 2 | ||
460 | 1 | 36 | 42 | 8 | 70A |
|
|
|
575 | 1 | 31 | 37 | 8 | 50A |
|
|
|
|
|
|
|
|
|
| ||
200 | 3 | 41 | 50 | 6 | 80A | Note 2 | ||
208 | 3 | 39 | 50 | 6 | 80A | Note 2 | ||
230 | 3 | 36 | 42 | 8 | 70A |
|
|
|
380 | 3 | 23 | 28 | 8 | 40A |
|
|
|
400 | 3 | 22 | 27 | 8 | 40A |
|
|
|
415 | 3 | 22 | 26 | 8 | 40A |
|
|
|
460 | 3 | 19 | 23 | 8 | 40A |
|
|
|
575 | 3 | 16 | 18 | 8 | 30A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note 1. Not rated is indicated by
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select The output cable size based upon the following chart.* |
| |||
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75°C rated: |
| |||
|
|
|
|
|
DUTY CYCLE | CURRENT | LENGTH UP 200FT. (61m) |
| |
100% | 300 | 2/0 |
| 2/0 |
60% | 350 | 2/0 |
| 2/0 |
|
|
|
|
|
*Lincoln Electric recommends using a minimum of 2/0 welding cable for pulse welding.
POWER WAVE 355M