INSTALLATION

A-10

 

 

 

I / O RECEPTACLE SPECIFICATIONS

TABLE A.2

WIRE FEEDER RECEPTACLE

PIN LEAD#

FUNCTION

A53 Communication Bus L

B54 Communication Bus H

C67A Electrode Voltage Sense

D

52

0vdc -

} 40VDC

E

51

+40vdc +

TABLE A.3

VOLTAGE SENSE RECEPTACLE

PIN LEAD#

FUNCTION

321A Work Voltage Sense

TABLE A.4

RS232 RECEPTACLE

PIN LEAD#

FUNCTION

2253 RS232 Receive

3254 RS232 Transmit

4

#

Pin5

5

#

Pin4

6

# #

Pin20

20

# #

Pin6

7251 RS232 Common

DIP SWITCH SETTINGS AND LOCATIONS

DIP switches on the P.C. Boards allow for custom configuration of the Power Wave. To access the DIP switches:

WARNING

ELECTRIC SHOCK can kill.

switch 7

 

auto mapping

off

 

auto mapping enable-default

on

 

auto mapping disabled

 

 

 

switch 8*

work sense lead

off

work sense lead not connected

on

work sense lead connected

 

 

 

*Factory setting for Switch 8 is OFF.

FIGURE A.7

CONTROL BOARD (DIP Switch Location)

1.Turn off power to the power source at the dis- connect switch.

Insulate yourself from the work and ground.

Always wear dry insulating gloves.

------------------------------------------------------------------------------------------

2.Remove the wrap around cover from the power source.

3.The control board is on the center assembly facing the case front. Locate the 8-position DIP switch and look for switch 8 of the DIP switch.

4.Using a pencil or other small object, slide the switch to the OFF position if the work sense lead is NOT connected. Conversely, slide the switch to the ON position if the work sense lead is present.

5.Replace the wrap around and screws. The PC board will “read” the switch at power up, and configure the work voltage sense lead appropriately.

FIGURE A.8

CONTROL BOARD DIP SWITCH: switch 1 = reserved for future use switch 2 = reserved for future use switch 3 = equipment group 1 selcted (default=off) switch 4 = equipment group 2 selcted (default=off)

switch 5 = reserved for future use switch 6 = reserved for future use switch 7 = auto mapping switch 8 = work sense lead

(See Figure A.8 for Dual Head Boom Feeder)

POWER WAVE 355M

Page 17