Installation Instructions | PDC Series |
INSTALLATION
Preparing for Installation
1.Attach
WARNING: FAILURE TO PROVIDE ADEQUATE STRUCTURAL STRENGTH FOR THIS COMPONENT CAN RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component.
2.Determine if NPT pipe is
•If NPT pipe is 1-1/2", proceed to Step 3.
•If NPT pipe is 2", loosen set screw and remove the
Pipe |
Coupler |
Set |
Screw |
Figure 1
3.Thread the PDC (A) onto the NPT pipe extension and tighten set screw. (See Figure 2)
NPT |
| Set | |
Pipe | 1 | ||
Screw | |||
| |||
| (A) |
|
Figure 2
4.Attach interface brackets to back of displays following instructions included with the interface brackets.
Installing Displays on PDC
WARNING: EXCEEDING MAXIMUM WEIGHT CAPACITY CAN LEAD TO SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT! It is the installers responsibility to ensure the total amount of weight placed on the mount does not exceed 400 lbs (181.44 kg) [200 lbs (90.72 kg) each faceplate].
WARNING: DISPLAY MAY WEIGH IN EXCESS OF
40 LBS (18.14 KG)! Always use two people and proper lifting techniques when installing or positioning display.
(A) |
Display |
Figure 3
1.While supporting each side of display, align four mounting buttons on display or interface bracket with four slots on PDC. (See Figure 3)
2.Lower each display into place listening for audible "click" to ensure recessed area of mounting buttons are properly seated in lower area of mounting holes.(See Figure 4)
5