Warning

The illustration shows the DC power supply terminal block. Wire the DC power supply as illustrated. The proper

 

 

 

wiring sequence is ground to ground, positive to positive, and negative to negative. The ground wire should always

 

 

 

be connected first and disconnected last. Statement 239

 

 

 

 

 

 

 

 

Warning

An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no

 

 

 

exposed portion of the DC-input power source wire extends from the terminal block plug. Statement 122

 

 

 

 

 

 

Caution

Do not overtorque the terminal block contact screws. Recommended torque is 8.0 ± 0.5 in-lb (0.9 ± 0.05 N-m).

 

 

 

 

Figure 8 DC Power Connections

Negative DC output

Terminal block

Positive DC input

Terminal block

A + + B

-DC, input B Return, input B Safety ground Return, input A -DC, input A

A +

+ B

95965

Return, input B +DC, input B Safety ground +DC, input A Return, input A

Step 5 Install the plastic covers over the terminal block. (See Figure 9.)

Step 6 Secure the wires using cable ties as shown in Figure 9. The chassis has a cable-tie attachment below and to the right of the terminal block.

Step 7 Turn on power to the DC circuit.

Figure 9 Wire Routing and Attachment

Cable tie

TD

RD

LP

AL

 

SEE

 

CD

 

 

 

 

MANUAL

 

 

 

BEFORE

 

 

 

INSTALLATION

Plastic covers

DSU 56K

SEE MANUAL BEFORE INSTALLATION

From DC power source

95824

Connecting Routers to the Cisco Redundant Power System

If your router uses the Cisco Redundant Power System (RPS), refer to the Cisco RPS Hardware Installation Guide for instructions about the power connections. To locate these documents, see the “Where to Go Next” section on page 23.

15

Page 15
Image 15
Cisco Systems 2691 quick start Be connected first and disconnected last. Statement, + B