5-28
Catalyst 2960 and 2960-S Switch Software Configuration Guide
OL-8603-09
Chapter 5 Administering the Switch
Managing the MAC Address Table
To remove static entries from the address table, use the no mac address-table static mac-addr vlan
vlan-id [interface interface-id] global configuration command.
This example shows how to add the static address c2f3.220a.12f4 to the MAC address table. When a
packet is received in VLAN 4 with this MAC address as its destination address, the packet is forwarded
to the specified port:
Switch(config)# mac address-table static c2f3.220a.12f4 vlan 4 interface
gigabitethernet0/1
Configuring Unicast MAC Address Filtering
When unicast MAC address filtering is enabled, the switch drops packets with specific source or
destination MAC addresses. This feature is disabled by default and only supports unicast static
addresses.
Follow these guidelines when using this feature:
Multicast MAC addresses, broadcast MAC addresses, and router MAC addresses are not supported.
If you specify one of these addresses when entering the mac address-table static mac-addr vlan
vlan-id drop global configuration command, one of these messages appears:
% Only unicast addresses can be configured to be dropped
% CPU destined address cannot be configured as drop address
Packets that are forwarded to the CPU are also not supported.
If you add a unicast MAC address as a static address and configure unicast MAC address filtering,
the switch either adds the MAC address as a static address or drops packets with that MAC address,
depending on which command was entered last. The second command that you entered overrides the
first command.
For example, if you enter the mac address-table static mac-addr vlan vlan-id interface
interface-id global configuration command followed by the mac address-table static mac-addr
vlan vlan-id drop command, the switch drops packets with the specified MAC address as a source
or destination.
If you enter the mac address-table static mac-addr vlan vlan-id drop global configuration
command followed by the mac address-table static mac-addr vlan vlan-id interface interface-id
command, the switch adds the MAC address as a static address.
You enable unicast MAC address filtering and configure the switch to drop packets with a specific
address by specifying the source or destination unicast MAC address and the VLAN from which it is
received.
Step 3 end Return to privileged EXEC mode.
Step 4 show mac address-table static Verify your entries.
Step 5 copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose