38-26
Catalyst 2960 and 2960-S Switch Software Configuration Guide
OL-8603-09
Chapter 38 Troubleshooting
Memory Consistency Check Routines

Displaying OBFL Information

To display the OBFL information, use one or more of the privileged EXEC commands in Table 38-3:
For more information about using the commands in Table 38-3 and for examples of OBFL data, see t he
command reference for this release.
Memory Consistency Check Routines
Note Memory consistency check routines are not supported on the Catalyst 2960-S switches.
The switch runs memory consistency check routines to detect and correct invalid ternary content
addressable memory (TCAM) table entries that can affect the performance of the switch.
If the switch cannot fix the error, it logs a system error message, specifying the TCAM space in which
the error is located:
Unassigned space: Unassigned TCAM table entries for the current SDM template.
Hulc Forwarding TCAM Manager (HFTM) space: Related to the Layer 2 and Layer 3 forwarding
tables.
Hulc Quality of Service (QoS)/access control list (ACL) TCAM Manager (HQATM) space: Related
to ACL and ACL-like tables such as QoS classification and policy routing.
The output from the show platform tcam errors privileged EXEC command provides information about
the TCAM memory consistency integrity on the switch.
Table 38-3 Commands for Displaying OBFL Information
Command Purpose
show logging onboard [module
[switch-number]] clilog
Displays the OBFL CLI commands that were entered on a standalone
switch or the specified stack members.
show logging onboard [module
[switch-number]] environment
Display the UDI information for a standalone switch or the specified
stack members and for all the connected FRU devices: the PID, the VID,
and the serial number.
show logging onboard [module
[switch-number]] message
Display the hardware-related messages generated by a standalone switch
or the specified stack members.
show logging onboard [module
[switch-number]] poe
Display the power consumption of PoE ports on a standalone switch or
the specified stack members.
show logging onboard [module
[switch-number]] temperature
Display the temperature of a standalone switch or the specified switch
stack members.
show logging onboard [module
[switch-number]] uptime
Display the time when a standalone switch or the specified stack members
start, the reason the standalone switch or specified stack members restart,
and the length of time that the standalone switch or specified stack
members have been running since they last restarted.
show logging onboard [module
[switch-number]] voltage
Display the system voltages of a standalone switch or the specified stack
members.