3-12
Cisco AVS 3180 Management Station Hardware Installation Guide
78-17292-01
Chapter3 Installing the AVS 3180
Connecting AC Power
Figure3-11 Console Connection
Connecting AC Power
Warning
This equipment must be grounded. Never defeat the ground conductor or
operate the equipment in the
absence of a suitably installed ground conductor.
Contact the appropriate electrical inspection authority
or an electrician if you are uncertain that suitable grounding is available.
Statement 1024
To connect AC power to your AVS 3180, follow these steps:
1. Ensure that you have reviewed the safety information outlined in Chapter2, “Preparing for
Installation.”
2. Plug the AC power cord into the power cord receptacle at the rear of the AVS 3180 (see Figure3-10).
3. Connect the other end of the power cord to a power source.
4. Power up all externally-connected devices.
5. Press the power control button on the front of the AVS 3180.
1RJ-45 180/rollover serial cable (null-modem) 3Console serial port
2DB-9 adapter to AVS console serial port 4DB-25 or DB-9 adapter to computer/console
serial port
i
143774
1
3
2
4