3-10
Cisco AVS 3180 Management Station Hardware Installation Guide
78-17292-01
Chapter3 Installing the AVS 3180
Installing Your AVS 3180
Figure3-9 Attaching the Right Bracket to the Right Side of the AVS 3180
2. Select a location in the rack to mount the AVS 3180, and then position the AVS 3180 and brackets
in the rack.
3. Align the right side bracket on the AVS 3180 to the front of the rack, and then insert and tighten the
two round head retaining screws to secure the AVS 3180 to the rack. Repeat this step to secure the
left side bracket to the rack.
Installing the AVS 3180 on a Workbench or Tabletop
When you install an AVS 3180 on a workbench or tabletop, ensure that the surface is clean and in a
secure location and that you have complied with the following requirements:
The chassis should be installed off of the floor. Dust that accumulates on the floor is drawn into the
interior of the chassis by the cooling fans. Excessive dust inside the AVS 3180 can cause
overtemperature conditions and component failures.
There must be approximately 19 inches (48.26 cm) of clearance at the front and rear of the chassis
for accessing network cables and equipment.
The AVS 3180 must receive adequate ventilation.
Follow these steps to install the AVS 3180 on a workbench or tabletop:
1. Remove any debris and dust from the tabletop or workbench, as well as from the surrounding area.
Ensure that your path between the AVS 3180 and its new location is unobstructed.
2. Place one rubber foot in each corner on the bottom of the AVS 3180. The rubber feet have an
adhesive backing. Peel the protective tape off of the adhesive, and adhere the feet to the four round,
recessed areas on the bottom of the chassis.
3. Place the chassis on the tabletop or workbench.
4. Ensure that no exhaust air from other equipment will be drawn into the chassis. Also, ensure that
there is adequate clearance at the front and rear of the chassis.
1Bracket 2Round head screws (6)
12