5Installing the Switch
Depending on the switch model, you can install the switch in a rack, on a wall, on or under a desk or
shelf, and with a magnet or rack-mount brackets. This section covers rack-, desk-, shelf-, and
magnet-mounting a switch. Depending on the switch, For alternate mounting procedures, see the
Catalyst 3560 Switch Hardware Installation Guide on Cisco.com.

Equipment That You Supply

You need this equipment to install the switch:
Number-2 Phillips screwdriver
Drill with a #27 drill bit (0.144-inch [3.7 mm])
Note A drill is required if you are securing the Catalyst 3560-8PC switch to a desk or a wall.

Before You Begin

When determining where to install the switch, verify that these guidelines are met:
Airflow around the switch and through the
vents is unrestricted.
Note We strongly recommend that you allow
at least 3 inches (7.6 cm) of clearance
around the ventilation openings.
Temperature around the switch does not
exceed 113˚F (45˚C).
Humidityaround the switch does not exceed
85 percent.
Altitude at the installation site is not greater
than 10,000 feet.
Do not place any items on the top of the
Catalyst 3560-8PC switch.
The heatsinks and the bottom of the
Catalyst 3560-8PC switch might be hot to
the touch if the switch is operating at its
maximumtemperature 113˚F (45˚C) and is in
an environment that exceeds normal room
temperature(such as in a closet, in a cabinet,
or in a closed or multirack assembly).
Allowat least 1.75 inches (4 cm) of clearance
above each Catalyst 3560-8PC switch in the
rack.