14
Warning
For connections outside the building where the equipment is installed, the following
ports must be connected through an approved network termination unit with integral
circuit protection: 10/100/1000 Ethernet. Statement 1044
Warning
Voltagesthat present a shock hazard may exist on Power over Ethernet (PoE) circuits if
interconnections are made using uninsulated exposed metal contacts, conductors, or
terminals. Avoid using such interconnection methods, unless the exposed metal parts
are located within a restricted access location and users and service people who are
authorized within the restricted access location are made aware of the hazard. A
restrictedaccess area can be accessed only through the use of a special tool, lock and
key or other means of security.Statement 1072
Rack-Mounting the Switch (All Catalyst 3560 Switches Except theCatalyst 3560-8PC Switch)
Note This section applies to all Catalyst 3560 switches except the Catalyst 3560-8PC switch. For
installationinformation for the Catalyst 3560-8PC switch, see “Securing the Switch on a Desk
orShelf (only the Catalyst 3560-8PC Switch)” section on page 17 and “Mounting the Switch
with a Magnet Panel (only the Catalyst 3560-8PC Switch)” section on page 19.
This section covers basic 19-inch rack-mounting. As an example, all the illustrations show the
Catalyst 3560G-48PS switch. You can install and connect other Catalyst3560 switches except the
Catalyst 3560-8PC switch as shown in these illustrations.