6Connecting to DC Power

6Connecting to DC Power

To connect the Catalyst 2950G-24-EI-DC or Catalyst 2950ST-24 LRE 997 switch to a DC-input power source, follow the steps in this section.

Equipment That You Supply

You need to supply these tools and equipment:

Ratcheting Phillips-head torque screwdriver

Panduit crimping tool

6-gauge copper ground wire

Four leads of 18-gauge copper wire

Wire stripping tool

Ground the Switch

Follow these steps:

Step 1 Remove the ground lug and the two number-10-32 screws from the switch (on the rear panel of the Catalyst 2950G-24-EI-DC switch and on the front panel of the Catalyst 2950ST-24 LRE 997 switch).

Step 2 If your 6-gauge ground wire is insulated, strip it to 0.5 inch (12.7 mm).

0.5 inch (12.7 mm) Ground the Switch0.5 inch (12.7 mm)