9
Cisco7206 VXR Router with ISA Security Policy
The 7206 VXR NPE-400 Router
Once the router has been configured to meet FIPS 140-1 Level 2 requirements, the router cannot be
accessed without signs of tampering. To seal the system, apply serialized tamper-evidence labels as
follows:
Clean the cover of any grease, dirt, or oil before applying the tamper evidence labels. Alcohol-based
cleaning pads are recommended for this purpose. The ambient air must be above 10C, otherwise the
labels may not properly cure.
The tamper evidence label should be placed so that the one half of the label covers the enclosure and
the other half covers the 7206 VXR NPE-400 Input/Output Controller.
The tamper evidence label should be placed over the Flash PC Card slots on the Input/Output
Controller.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the port adapter slot 1.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the port adapter slot 2.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the port adapter slot 3.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the port adapter slot 4.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the port adapter slot 5.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the port adapter slot 6.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the network processing engine.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the power supply plate.
The tamper evidence label should be placed so that one half of the label covers the enclosure and
the other half covers the redundant power supply plate.
The labels completely cure within five minutes.