3-16
Cisco IAD2430 Series Integrated Access Devices Hardware Installation Guide
OL-4234-06
Chapter 3 Installing Cisco IAD2430 Series IADs
Installing the Ground Connection
Figure 3-13 Crimping a Ground Lug onto the Ground Wire
Step 4 Attach the ground lug or ring terminal to the chassis as shown in Figure 3-14, Figure 3-15, or
Figure 3-16. For the ground lug, use the two screws with captive locking washers provided. For a ring
terminal, use one of the screws provided. Use a number 2 Phillips screwdriver, and tighten the screws
to a torque of 8 to 10 in-lb (0.9 to 1.1 N-m).
Note You can orient the crimped end of the ground lug in either direction (right or left).
Figure 3-14 NEBS-Compliant Chassis Ground Connection Using Ground Lug
Figure 3-15 Ground Lug Location on the Cisco IAD2435 IAD
10360
88844
Ground lug
1Grounding lug
232068
IAD2435-8FXS
12V DC SA
CONSOLE
AUX
FastEthernet
WAN
0/1 0/0
T1/E1
FXS
1