Table 2-1

Specifications for Operating and Nonoperating Environments

 

 

 

 

 

Specification

 

Minimum

Maximum

 

 

 

Temperature, ambient operating

32°F (0°C)

114°F (40°C)

 

 

 

Temperature, ambient nonoperating and storage

–13°F (–25°C)

95°F (70°C)

 

 

 

Humidity, ambient (noncondensing) operating

5%

95%

 

 

 

Humidity, ambient (noncondensing) nonoperating and

5%

95%

storage

 

 

 

 

 

 

Altitude, operating and nonoperating

Sea level

10,000 ft (3,050 m)

 

 

 

Vibration, operating

10 to 200 Hz, 0.0005 g (1 oct./min.)

 

 

 

Vibration, nonoperating

10 to 100 Hz, 0.0065 g (1 oct./min.)

 

 

 

 

Preventive Site Configuration: Maintaining Normal Operation

Planning a proper location for the Cisco uBR904 cable modem is essential for successful system operation. Equipment placed too close together or inadequately ventilated can cause system overtemperature conditions. In addition, poor equipment placement can make system maintenance difficult. Following are precautions that can help avoid problems during installation and ongoing operation.

General Precautions

Follow these general precautions when planning your equipment locations and connections:

We recommend keeping the Cisco uBR904 cable modem off the floor and out of any area that tends to collect dust.

Follow ESD prevention procedures to avoid damage to equipment. Damage from static discharge can cause immediate or intermittent equipment failure.