Maintenance

Time Intervals

Operation or Inspection

Corrective Action

 

 

 

Daily or as required

Visually inspect sight glass in air line filter at

If moisture and oil are collecting in bowl, auto-

 

inlet. (Refer to Item 4, Figure 4.)

drain is not working. Clean, repair or replace

 

 

auto-drain.

 

 

 

 

Check buck padding.

Clean padding. Replace padding if it is torn or

 

 

brittle or has burn spots.

 

 

 

 

Visually inspect press head for discoloration or

Clean press head with a head surface cleaner as

 

stickiness.

needed.

 

 

 

Weekly

Inspect air line filter for sediment.

Clean air filter if dirt is present.

 

 

 

 

Inspect all safety labels. Refer to Parts Manual

Replace labels which are damaged, missing or

 

for location and description of labels.

unreadable.

 

 

 

Every two weeks

Inspect steam strainers in steam inlet and outlet

Clean steam strainer if dirt is present.

 

lines and in traps.

 

 

 

 

Monthly

Inspect customer-furnished steam traps per

Clean customer-furnished steam traps if dirt is

 

instructions provided with traps.

present.

 

 

 

 

Check all steam and air connections for visual

Tighten any loose connections. Replace lines

 

signs of leakage.

where necessary.

 

 

 

 

Check condition of the flexible steam hoses.

Replace steam hoses with broken braids.

 

 

 

Every six months

Remove all covers and check cap screws,

Tighten as required.

 

fittings and cylinders for security of

 

 

attachment.

 

 

 

 

 

Table 2

 

Cleaning Press Head

Cleaning press head is periodically required. Press head requires cleaning if discoloration transfers from head to garments or garments stick to head as it opens.

WARNING

To avoid possible serious injury, heads should be cleaned ONLY by properly trained personnel.

W342

WARNING

If using a surface cleaner which requires heat to the press, use industry approved heat protective mitt or other heat protective device as press heads are cooling down.

W344

Once precautions in above WARNINGS have been met, follow directions provided with surface cleaner.

WARNING

To avoid possible serious injury, ALWAYS shut off services to press BEFORE cleaning press heads:

Shut off AND lock out ALL electric power to press.

Shut off AND lock out ALL air pressure to press using relieving shut-off valve at air supply inlet.

Reduce to zero AND lock out ALL steam pressure to press.

Let heated surfaces cool.

W343

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

AJ1032