Maintenance
Time Intervals | Operation or Inspection | Corrective Action |
|
|
|
Daily or as required | Visually inspect sight glass in air line filter at | If moisture and oil are collecting in bowl, auto- |
| inlet. (Refer to Item 4, Figure 4.) | drain is not working. Clean, repair or replace |
|
| |
|
|
|
| Check buck padding. | Clean padding. Replace padding if it is torn or |
|
| brittle or has burn spots. |
|
|
|
| Visually inspect press head for discoloration or | Clean press head with a head surface cleaner as |
| stickiness. | needed. |
|
|
|
Weekly | Inspect air line filter for sediment. | Clean air filter if dirt is present. |
|
|
|
| Inspect all safety labels. Refer to Parts Manual | Replace labels which are damaged, missing or |
| for location and description of labels. | unreadable. |
|
|
|
Every two weeks | Inspect steam strainers in steam inlet and outlet | Clean steam strainer if dirt is present. |
| lines and in traps. |
|
|
|
|
Monthly | Inspect | Clean |
| instructions provided with traps. | present. |
|
|
|
| Check all steam and air connections for visual | Tighten any loose connections. Replace lines |
| signs of leakage. | where necessary. |
|
|
|
| Check condition of the flexible steam hoses. | Replace steam hoses with broken braids. |
|
|
|
Every six months | Remove all covers and check cap screws, | Tighten as required. |
| fittings and cylinders for security of |
|
| attachment. |
|
|
|
|
| Table 2 |
|
Cleaning Press Head
Cleaning press head is periodically required. Press head requires cleaning if discoloration transfers from head to garments or garments stick to head as it opens.
WARNING
To avoid possible serious injury, heads should be cleaned ONLY by properly trained personnel.
W342
WARNING
If using a surface cleaner which requires heat to the press, use industry approved heat protective mitt or other heat protective device as press heads are cooling down.
W344
Once precautions in above WARNINGS have been met, follow directions provided with surface cleaner.
WARNING
To avoid possible serious injury, ALWAYS shut off services to press BEFORE cleaning press heads:
•Shut off AND lock out ALL electric power to press.
•Shut off AND lock out ALL air pressure to press using relieving
•Reduce to zero AND lock out ALL steam pressure to press.
•Let heated surfaces cool.
W343
14 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | AJ1032 |