(1) Connector pin configuration
No. | Signal | Function |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | FG | Frame ground |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
2 | DRAWER1 | Cash drawer 1 drive signal |
|
|
|
|
|
|
|
|
|
|
3 | DRSW | Cash drawer switch input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | VDR | Cash drawer drive power supply |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 | DRAWER2 | Cash drawer 2 drive signal |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
6 | GND | Signal ground (common ground on |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| circuits) |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Connector used:
Applicable connector:
(2)Electric characteristics
1)Drive voltage: 24 VDC
2)Drive current: Approx. 1 A max. (not to exceed 510 ms.)
3)DRSW signal: Signal levels: “L” = 0 to 0.8 V, “H” = 2 to 3.3 V
(3)DRSW signal
DRSW signal status can be tested with the DLE+EOT, GS+a, or GS+r command.
(4)Drive circuit
Cash drawer
Shielded
Cash drawer open/ close switch
Cash drawer |
|
|
| Printer |
|
|
CAUTION
Cash drawers 1 and 2 cannot be operated at the same time.
The solenoid used for the cash drawer should be 24 Ω or more. Do not allow the electric current to exceed 1 A. Excessive current could damage or burn out the circuits.
— 21 —