CBM-710/720/730/750 User ’s Manual

(8) Initial Set Command

D8

 

 

 

 

 

 

D1

0

0

0

1

0

0

0

1

 

 

 

 

 

 

 

 

DC1 (11)H

The controller is initialized by this command and the following conditions are established.

*Internal input buffer cleared

*Normal character mode selected

*Black color print mode selected

*Skip designation cancelled

*Page length set to 66 lines

*Line feed pitch set to 219 inch (graphic type only)

(9)Inverted character command

D8

 

 

 

 

 

 

D1

 

0

0

0

1

0

0

1

0

DC2 (12)H

 

 

 

 

 

 

 

 

 

This command specifies inverted characters. By entering this command at the beginning of print data and then sending the data to the controller, all of the following characters will be printed upside down. This command remains valid until, either it is entered again or the initial set command is entered.

(10) Buzzer Command

D8

 

 

 

 

 

 

D1

0

0

0

0

0

1

1

1

 

 

 

 

 

 

 

 

BEL (07)H

Command to activate the alarm buzzer for 0.3 second period.

38

CITIZEN

Page 44