CBM-710/720/730/750 User ’s Manual

(17) Skip Perforation Command

 

 

 

 

 

 

 

D8

 

 

 

 

 

D1

1st byte

0

0

0

1

1

0

1

1

 

 

 

 

 

 

 

 

 

ESC (1B)H

2nd byte

D8

 

 

 

 

 

 

D1

0

1

0

0

1

1

1

0

 

 

 

 

 

 

 

 

N (4E)H

3rd byte

D8

D1

N7 N6 N5 N4 N3 N2 N1

n (Binary digital)

This command feeds the paper (skips) n lines without any printing. However, this cannot exceed the length of one page (1 n 126)

(18) Skip Perforation Cancel Command

 

D8

 

 

 

 

 

 

D1

1st byte

0

0

0

1

1

0

1

1

 

 

 

 

 

 

 

 

 

ESC (1B)H

2nd byte

D8

 

 

 

 

 

 

D1

0

1

0

0

1

1

1

1

 

 

 

 

 

 

 

 

0 (4F)H

This command cancels the skip perforation function.

(19) Validation Print Command

 

 

 

 

 

 

 

D8

 

 

 

 

 

D1

1st byte

0

0

0

1

1

0

1

1

 

 

 

 

 

 

 

 

 

ESC (1B)H

2nd byte

3rd byte

D8

 

 

 

 

 

 

D1

 

0

1

0

1

0

0

0

0

P (50)H

 

 

 

 

 

 

 

 

 

D8

 

 

 

 

 

 

D1

 

0

0

0

0

0

0

1

0

2 (02)H

 

 

 

 

 

 

 

 

 

Validation printing is performed by this command (one line only).

* This command cannot be used for printers with cutter specifications (Type A).