5.4 Monitoring the Print Head Overheating

If the temperature exceeds 65°C for some reason, the printer automatically stops printing with Power LED indication of “Error” to protect the print head.

If the head temperature returns to 60°C or below, the printer is ready for printing.

5.5 Self Testing and Internal Settings

Keep the LF switch pressed down.

Press the ON/OFF switch down.

Release the ON/OFF switch.

Release the LF switch.

Immediately after releasing the LF switch the printer will print out a SELF TEST report.

At the end of the report, density, auto-power off time, head temperature, battery output voltage, communication mode, baud rate (for serial communication) are printed.

The number of marks * in the parentheses aside battery output voltage shows a level of battery charge in 5 steps.

5.6 Print Area

4 mm

Paper width - 58 mm

Print area - 48 mm

6 mm

Print area

Thermal paper

— 32 —