Canon SX60, X600 Dots, Format DOTS=Number of dots Number, Example Setting, Range Dots

Models: SX60 X600

1 190
Download 190 pages 0 b
Page 29
Image 29

User Command Specifications

9. Details of command DOTS

1

Commands

DOTS

 

Mode

Control

Setting

Reference

Function

Total number of dots adjustment

 

 

 

 

 

 

 

 

 

 

 

Format

DOTS=<Number of dots: Number>

 

 

 

 

 

 

 

 

 

Parameter Number of dots

 

 

 

 

 

The RANGE command can be used to obtain the parameter range that can be set at

Number

 

that time.

 

 

 

 

 

 

 

 

 

For details, refer to the RANGE command.

 

 

 

 

 

 

 

 

 

Response "i:OK" is returned if the parameter was set properly.

 

 

 

 

 

For all other responses, refer to "Error List."

 

 

 

 

 

 

 

 

 

 

Description

1 This designates the total number of dots for one horizontal period.

 

 

 

 

-1 It can be executed when the projector is in both the remote mode and power-onstatus at the same time.

A "busy" response is given while the zoom or focus lens is being driven. (Refer to the ZCONTDRV command and FCONTDRV command.)

Furthermore, it may not be possible to execute the command with some input signals. -2 This command is the same as the menu functions in the table below.

Model Menu

SX50 [Display settings] - [Input signal settings] - [Total number of dots adjustments]

SX6

SX60 [Display settings] - [Input signal settings] - [Total number of dots]

X600

-3 The GET command can be used to obtain the current total number of dots. For details, refer to the GET command.

Example Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> DOTS=1650

 

 

 

 

 

 

The total number of dots is 1650.

 

 

 

 

 

 

< i:OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> GET DOTS or ?DOTS

 

 

 

 

 

This retrieves the total number of dots.

 

 

 

 

 

< g:DOTS=1200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Obtain settable parameter range (Min, Max)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> RANGE DOTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< r:DOTS=N, 0, 4096

 

 

 

 

 

Any value from 0 to 4096 can be set for the total dots.

 

 

 

 

* Commands are indicated by ">", and responses are indicated by "<".

 

 

 

 

 

 

Commands

 

SX50

 

SX6

 

SX60

X600

 

 

 

 

 

 

 

 

 

 

supported

01.00**

 

01.01**

 

01.01**

01.01**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supported Command States

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Power

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

Mode

Remarks

 

OFF

ON

PM

D-RGB

A-RGB1

A-RGB2

Comp

Video

 

S-Video

D-Video

SCART

None

Remote

Local

 

SX50

×

×

×

 

 

 

×

×

 

×

 

×

×

 

SX6

×

×

×

 

 

 

×

×

 

×

×

 

×

×

×

 

SX60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If the command cannot be supported, 'INVALID_MODE,' 'NOT_POWER_SUPPLIED' or 'INVALID_SOURCE' is returned as an error response.

*If the necessary signals are not input, 'INVALID_SIGNAL (*****)' or 'NO_SIGNAL' is returned.

*"i:BUSY" may be returned if the power status is being switched.