User Command Specifications

9.Details of command FCONTDRV

Commands

FCONTDRV

 

Mode

Control

Setting

Reference

Function

Focus lens continuous drive control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

 

FCONTDRV=<Focus lens continuous control parameter:ID>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Focus lens continuous control parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Meaning

 

 

 

 

 

 

 

 

STOP

This stops the focusing.

 

 

 

 

 

 

 

 

FAR

This initiates focusing toward the far end.

 

 

 

 

 

 

 

 

NEAR

This initiates focusing toward the near end.

 

 

 

 

 

ID

 

The parameters which can be set at any given point in time can be obtained using the

 

 

 

RANGE command.

 

 

 

 

 

 

 

For details, refer to the RANGE command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response

"i:OK" is returned when the drive was completed successfully.

 

 

 

 

 

 

 

For all other responses, refer to "Error List."

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

This command is used to drive the focus lens.

 

 

 

 

 

 

(1)It can be executed when the projector is in both the remote mode and power-onstatus at the same time.

However, only the "STOP" parameter takes effect while the focus lens is being driven, and a "busy" response is given while the zoom lens is being driven.

Refer to the ZCONTDRV command and FCONTDRV command.

(2)This command functions in the same way as when first the "FOCUS" button on the remote control or main unit panel is pressed and then the "↑" or "↓" button is pressed.

(3)Focus drive is started by specifying "NEAR" or "FAR." To stop the drive, add the "STOP" parameter and send this command.

If no instruction was given to stop the drive, the drive stops at the drive direction end.

(4)The following commands are acknowledged during focus drive, but focus drive will also stop at the same time.

In the case of any other commands, "i:BUSY (FOCUS)" is returned unconditionally, and focus drive continues.

a.REMOTE

b.LOCAL

c.POWER

d.FCONTDRV=STOP

(5)The following commands are acknowledged during focus drive, and a response is returned while the drive continues.

a. GET MODE

e.

GET PRODCODE

b. GET POWER

f.

GET ROMVER

c. GET ERR

g.

GET COMVER

d. GET LAMPCOUNTER

 

 

(6)Focus drive stops when the "POWER" button on the remote control or main unit panel is pressed during focus drive.

Example Control

 

 

 

 

 

 

 

 

 

 

> FCONTDRV=NEAR

 

 

Control over the focusing to the near end is started.

 

 

< I:OK

 

 

 

 

 

 

 

 

 

 

Range acquisition

 

 

 

 

 

 

 

 

> RANGE FCONTDRV

 

 

 

 

 

 

 

 

< r:FCONTDRV=I, STOP, FAR, NEAR

"STOP," "FAR" or "NEAR" can be set for focus

 

 

 

 

 

 

 

lens continuous drive.

 

 

 

 

 

 

 

 

 

 

 

Commands

SX50

SX6

 

SX60

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

supported

01.00**

01.01**

 

01.01**

01.01**

 

 

 

 

 

 

×

 

 

 

 

 

 

 

When a command is not supported, "e:0002 INVALID_COMMAND" is returned.

 

 

 

 

 

 

 

 

 

 

 

Supported Command States

Model

Power supply

 

 

 

 

Input

 

 

 

 

Mode

Remarks

 

OFF

ON

PM

D-RGB

A-RGB1

A-RGB2

Comp

Video

S-Video

D-Video

SCART

None

Remote

Local

 

SX50

 

SX6

×

×

×

 

SX60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. *When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.