User Command Specifications

9.Details of command GET ROMVER

1

Commands

GET ROMVER

Mode

Control

Setting

Reference

Function

ROM version inquiry

 

 

 

 

 

 

 

 

 

 

Format

GETROMVER

 

 

 

 

 

?ROMVER

 

 

 

 

 

 

 

 

 

 

Response

g:ROMVER="<ROM VERSIONCharacter string>"

 

 

 

 

 

<ROM VERSION> := 99.9999

 

 

 

Character

 

For all other responses, refer to "Error List."

 

 

 

string

 

 

 

 

 

 

 

 

 

 

Description This inquires about the product name of the projector.

 

 

 

 

-1 This inquiry can be executed in any status provided that AC power is supplied to the projector. For the "SX50," the projector must be in the remote mode and power-onstatus.

Example > GET ROMVER or ? ROMVER