Canon X600, SX60 Vks/Hks, Format VKS=Vertical keystone distortion value Number, Range HKS

Models: SX60 X600

1 190
Download 190 pages 0 b
Page 56
Image 56

User Command Specifications

9. Details of command VKS/HKS

1

Commands

VKS/HKS

 

 

 

 

 

 

 

 

 

 

Mode

Control

Setting

Reference

Function

Vertical/Horizontal keystone setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

 

VKS=<Vertical keystone distortion value: Number>

 

 

 

 

 

 

 

 

 

 

 

 

HKS=<Horizontal keystone distortion value: Number>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Vertical/horizontal keystone distortion values

 

 

 

 

 

 

 

 

 

 

 

 

 

The RANGE command can be used to obtain the parameter range that can be set at

 

 

Number

 

 

 

that time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For details, refer to the RANGE command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response

"i:OK" is returned if the parameter was set properly.

 

 

 

 

 

 

 

 

 

 

 

 

 

For all other responses, refer to "Error List."

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description

This sets the vertical and horizontal keystones.

 

 

 

 

 

 

 

 

 

 

 

 

 

-1

It can be executed when the projector is in both the remote mode and power-onstatus at the

 

 

 

 

same time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A "busy" response is given while the zoom or focus lens is being driven.

 

 

 

 

 

 

 

 

 

(Refer to the ZCONTDRV command and FCONTDRV command.)

 

 

 

 

 

 

 

 

-2

This command is identical to pressing the “KEYSTONE” button on the remote control or front pa

 

 

 

-3

The settable keystone range varies depending on the input signal, screen size, number of

 

 

 

-4

horizontal and vertical dots, and other factors.

 

 

 

 

 

 

 

 

 

 

 

 

 

Changing the vertical keystone value modifies the setting range of the horizontal keystone

 

 

 

-5

value, and changing the horizontal keystone value modifies the setting range of the vertical

 

 

 

Use the “RANGE” command to obtain the range of settable values immediately before setting

 

 

 

-6

the vertical value and horizontal value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The GET command can be used to obtain the current vertical/horizontal keystone value.

 

 

 

 

 

For details, refer to the GET command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> VKS=-23

 

 

 

 

 

This sets the vertical keystone to –23.

 

 

 

 

 

 

< i:OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> HKS=10

 

 

 

 

 

This sets the horizontal keystone to 10.

 

 

 

 

 

 

< i:OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> GET VKS or ?VKS

 

 

This retrieves the vertical keystone.

 

 

 

 

 

 

 

 

< g:VKS=-23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> GET HKS or ?HKS

 

 

This retrieves the horizontal keystone.

 

 

 

 

 

 

< g:HKS=-23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Obtain settable parameter range (Min, Max)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> RANGE HKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< r:HKS=N,-30,30

 

 

 

Any value from -30 to 30 can be set for the horizontal

 

 

 

 

 

 

 

 

 

 

 

 

 

keystone distortion.

 

 

 

 

 

 

 

 

 

 

 

* Commands are indicated by ">", and responses are indicated by "<".

 

 

 

 

 

 

 

 

Commands

 

SX50

 

SX6

 

SX60

X600

 

 

 

 

 

 

 

 

 

 

 

 

supported

01.00**

 

01.01**

 

01.01**

01.01**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supported Command States

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Power

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

Mode

 

Remarks

 

OFF

ON

PM

D-RGB

A-RGB1

A-RGB2

Comp

Video

 

S-Video

D-Video

SCART

None

Remote

 

Local

 

 

SX50

×

×

 

 

 

 

 

×

 

×

 

 

SX6

×

×

 

 

 

 

 

 

×

 

 

SX60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If a command cannot be supported, 'INVALID_MODE' or 'NOT_POWER_SUPPLIED' is returned as an error response.