User Command Specifications10. Error List

10. Error List

 

 

TYPE

 

Errors

 

 

 

Item

Code

Error character strings

supported by

Error

Remedy

model

 

 

 

 

 

(1) (2) (3) (4)

 

 

1

0001

e

BAD_SEQUENCE

○ ○ ○ ○ Communication sequence error

Wait until the response is received to send

the command.

 

 

 

 

 

 

 

2

0002

e

INVALID_COMMAND

○ ○ ○ ○ Command is invalid (undefined).

Send the correct command.

3

0003

e

INVALID_MODE

○ ○ ○ ○ The designated command cannot be

Switch the mode using the REMOTE or

 

 

 

 

 

 

executed in this mode.

LOCAL command.

4

0004

e

INVALID_FORMAT

○ ○ ○ ○ The command format is incorrect.

Send in the correct command format.

5

0005

e

NOT_POWER_SUPPLIED

○ ○ ○ ○ Power is not being supplied.

Use the POWER ON command to turn on

the power.

 

 

 

 

 

 

 

6

i

BUSY

○ ○ ○ ○ Mode switching or processing inside the

Wait until the power supply state changes

 

 

 

 

 

 

projector is underway.

to “ON”, “OFF”, or “PMM”.

7

000A

e

INVALID_PARAMETER

 

 

The parameter (type) is invalid

Use the correct parameter(s).

○ ○ ○ ○ (undefined).This includes the case when

 

 

 

 

 

 

the number of parameters is incorrect.

 

8

000B

e

JOB_TIMEOUT

○ ○ ○ ○ SX50 internal processing has timed out.

Resend the command.

9

w

USER_COMMAND_VERSION_IS_UPDATED ○ ○ ○ ○ The user command version is being updated.

Use GET COMVER to obtain the latest

 

 

 

 

 

 

 

user command version.

10

i

BUSY (FOCUS)

○ ○ ○ The focus lens is now being driven.

Wait until the focus lens drive stops.

 

 

 

 

 

 

i

BUSY (ZOOM)

○ ○ ○ The zoom lens is now being driven.

Wait until the zoom lens drive stops.

 

 

 

 

 

 

 

 

 

F001

e

SYSTEM (UNKNOWN)

○ ○ ○ ○ An internal error occurred.

Resend the command.

11

F002

e

SYSTEM (FOCUS)

○ ○ ○ An error occurred in AUTOSETEXE=FOCUS.

Eliminate the cause of the error, and

F004

e

SYSTEM (AUTO_KEYSTONE)

○ ○ ○ An error occurred in AUTOSETEXE=VKS.

 

resend the command.

 

F005

e

SYSTEM (SCREEN_COLOR)

○ ○ ○ An error occurred in AUTOSETEXE=SCRN.

 

 

12

E0XX

e

COMMUNICATION_ERROR

○ ○ ○

A communication protocol violation

Resend the command.

 

 

 

 

 

 

occurred in the projector.

 

 

 

 

 

 

 

This cannot be executed with the current

 

13

200X

e

INVALID_SOURCE (****)

○ ○ ○ ○ input source.

Change the input source.

 

 

 

 

 

 

The current input source is indicated in

 

 

 

 

 

 

 

parentheses.

 

 

2010

e

NO_SIGNAL

○ ○ ○ ○ There is no signal input.

Input the signal.

14

 

 

 

 

 

This cannot be executed with the current

 

201X

e

INVALID_SIGNAL (****)

○ ○ ○ ○ input signal.

Change the input signal.

 

 

 

 

 

 

The current input signal is indicated in

 

 

 

 

 

 

 

parentheses.

 

 

 

i

BUSY (NOW_SETTING)

○ ○ ○ ○ Signal setting (detection) is in progress.

 

 

 

i

BUSY

○ ○ ○ ○ Preparing to switch to power management

Wait until the processing is completed.

 

 

 

(POWER_MANAGEMENT_READY)

 

 

standby.

 

15

i

BUSY (INTERNAL_PROCESS)

○ ○ ○ ○ Heavy processing is in progress.

 

i

BUSY (FOCUS)

○ ○ ○ The focus lens is now being driven.

Wait until the focus lens drive stops.

 

 

 

 

 

 

 

 

 

 

i

BUSY (ZOOM)

○ ○ ○ The zoom lens is now being driven.

Wait until the zoom lens drive stops.

 

 

 

 

 

 

 

 

 

0801

 

 

 

 

Numerical parameters are invalid or

Use the RANGE command to obtain the

16

0802

e

INVALID_VALUE

 

 

parameter range, and then use a

○ ○ ○ ○ outside the range.

 

 

 

 

 

 

 

parameter within the range.

 

1001

e

TERMINAL_OUT

 

 

The input cannot be selected since the

Use the TERMINAL command to set the

 

 

terminal to input, and then select the input

 

 

terminal is set to output.

 

 

 

 

 

 

again.

 

 

 

 

 

 

 

 

1002

e

NO_LOGO_CAPTURED

○ ○ ○ ○ Processing cannot be executed since the

Register the user image.

 

 

 

 

 

 

user image is not registered.

 

 

1003

e

IP_NOT_AVAILABLE

○ ○ ○ ○ IP conversion cannot be performed.

Change to the correct input signal.

17

1004

e

POWER_MANEGEMENT_OFF

○ ○ ○ DPON cannot be set to ON when PMM is

Set DPON to ON when PMM is not OFF.

 

 

 

 

 

 

OFF.

 

 

1005

e

DIRECT_POWER_ON

○ ○ ○ PMM cannot be set to OFF when DPON is

Set DPON to OFF.

 

 

 

 

 

 

ON.

 

 

1006

e

NOW_BLANK

 

 

AUTOSETEXE=FOCUS or SCRN cannot

After setting BLANK to ON, resend the

 

○ ○ ○ be executed since BLANK is ON.

command.

 

203X

e

INVALID_RESOLUTION (***)

○ ○ ○ ○ The input signal resolution is not correct.

Change to the correct resolution of the

 

input signal.

 

 

 

 

 

 

 

18

i

INPUT_NOT_FOUND

 

 

The input was not switched since no input signal

There is no action to be taken since the

○ ○ ○ was found with AUTOSETEXE=INPUT.

status has been notified.

The error code is expressed as a four-digit hexadecimal character string. ‘X’ is a number from ‘0’ to ‘9’ or letter from ‘A’ to ‘F’.

Errors with the newer item numbers have higher priority. (When there is more than one error, the highest level error is returned. However, error priority is the same within the same item number.)

Given below is the correspondence between the numbers (1) to (4) in the "Errors supported by model" column and the models concerned.

(1)SX50

(2)SX6

(3)SX60

(4)X600

PAGE 177

Page 185
Image 185