Canon SX60 Format DPON=Direct power-on setting parameter:ID Parameter, Dpon=On, Range Dpon

Models: SX60 X600

1 190
Download 190 pages 0 b
Page 71
Image 71

User Command Specifications

9. Details of command DPON

Commands

DPON

 

 

Mode

Control

Setting

Reference

Function

Direct power-on setting

 

 

 

Format

 

DPON=<Direct power-on setting parameter:ID>

 

 

 

 

 

 

Parameter

Direct power-on setting parameters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Meaning

 

 

 

 

 

 

 

 

ON

This sets direct power-on to ON.

 

 

 

 

 

 

 

 

OFF

This sets direct power-on to OFF.

 

 

 

 

 

ID

 

The parameters which can be set at any given point in time can be obtained using the

 

 

 

 

 

RANGE command.

 

 

 

For details, refer to the RANGE command.

 

 

 

 

 

 

 

 

 

Response

"i:OK" is returned if the parameter was set properly.

 

For all other responses, refer to "Error List."

 

 

Description

This command is used to set direct power-on function to ON or OFF.

(1)It can be executed when the projector is in both the remote mode and power-onstatus at the same time.

However, a "busy" response is given while the zoom or focus lens is being driven.

Refer to the ZCONTDRV command and FCONTDRV command.

(2)This command functions in the same way as when "System settings" - "Direct power-on" are selected on the menu.

(3)Direct power-on cannot be set to ON when "OFF" has been selected as the power management setting.

("e:1004 POWER_MANAGEMENT_OFF" is returned.)

(5)The current direct power-on setting can be obtained using the GET command. For details, refer to the GET command.

 

Example Setting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> DPON=ON

 

 

Direct power-on is set to ON.

 

 

 

 

 

 

 

 

 

 

< i:OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> GET DPON or ?DPON

 

The current direct power-on setting is obtained.

 

 

 

 

 

 

< g:DPON=ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Acquisition of parameters which can be set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

> RANGE DPON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< r:DPON=I,ON,OFF

 

 

"ON" or "OFF" can be set for direct power-on.

 

 

 

 

 

 

*Commands are indicated by ">", and responses are indicated by "<".

 

 

 

 

 

 

Commands

 

SX50

SX6

 

SX60

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supported

01.00**

01.01**

 

01.01**

01.01**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

×

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When a command is not supported, "e:0002 INVALID_COMMAND" is returned.

 

 

 

 

 

Supported Command States

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Power supply

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

Mode

Remarks

 

OFF

ON

PM

D-RGB

A-RGB1

A-RGB2

Comp

Video

 

S-Video

D-Video

 

SCART

None

Remote

Local

 

SX50

 

 

 

 

 

SX6

×

×

 

 

 

 

×

 

SX60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. *When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.

PAGE 63

Page 71
Image 71
Canon SX60, X600 specifications Format DPON=Direct power-on setting parameter:ID Parameter, Dpon=On, Range Dpon