User Command Specifications

9Details of command GET ERR

1

Commands

GET ERR

 

 

 

Mode

Control

Setting

Reference

Function

Error information inquiry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

GETERR

 

 

 

 

 

 

 

 

 

 

 

?ERR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response

g:ERR=<ErrorID:ID>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error ID

Meaning

Errors supported by model

 

 

 

 

SX50

SX6

SX60

X600

 

 

 

 

 

 

 

 

 

 

NO_ERROR

No error

 

 

 

 

 

ABNORMAL_TEMPERATUR

Temperature error

 

 

 

 

 

FAULTY_LAMP

Lamp error

 

 

 

 

 

FAULTY_LAMP_COVER

Lamp cover error

 

 

 

 

 

FAULTY_COOLING_FAN

Cooling fan error

 

 

ID

 

 

FAULTY_POWER_SUPPLY

Power supply error

 

 

 

 

FAULTY_AK

AK error

 

 

 

 

 

FAULTY_ASC

ASC error

 

 

 

 

 

FAULTY_AF

AF error

 

 

 

 

 

FAULTY_POWER_ZOOM

Zoom error

 

 

 

 

 

FAULTY_POWER_FOCUS

Focus error

 

 

 

For all other responses, refer to "Error List."

Description This inquires about the current error information.

-1 This inquiry can be executed in any status provided that AC power is supplied to the projector. For the "SX50," the remote mode must be established.

-2 Information when the warning LED of the projector is flashing can be obtained. "NO_ERROR" is returned when the warning LED is not lighted.

Example > GET ERR or ? ERR

<g:ERR=FAULTY_LAMP

*Commands are indicated by ">", and responses are indicated by "<".

Commands

SX50

SX6

SX60

X600

 

 

 

 

supported

01.00**

01.01**

01.01**

01.01**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supported Command States

Model

Power

 

 

 

 

Input

 

 

 

 

Mode

Remarks

 

OFF

ON

PM

D-RGB

A-RGB1

A-RGB2

Comp

Video

S-Video

D-Video

SCART

None

Remote

Local

 

SX50

×

 

SX6

 

SX60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If a command cannot be supported, 'INVALID_MODE' is returned as an error response.

*"i:BUSY" may be returned if the power status is being switched.

PAGE 122

Page 130
Image 130