User Command Specifications

9.Details of command RANGE ZSTEPDRV

Commands

RANGE ZSTEPDRV

Mode

Control

Setting

Reference

 

 

 

 

 

 

 

 

 

 

 

 

 

Function Zoom lens step drive control option request

 

 

 

 

 

 

 

 

 

 

 

 

Format

RANGE□ZSTEPDRV

 

 

 

 

 

 

 

 

 

 

Response

r:ZSTEPDRV=I, <Setting option 1>, <Setting option 2>, …, <Setting option n>

 

 

 

For all other responses, refer to "Error List."

 

 

 

 

ID

 

 

 

 

 

 

 

 

 

 

 

 

Description

This command is used to inquire about the parameter options which enable the step drive of the zoom lens.

(1)This inquiry can be mades when the projector is in both the remote mode and power-onstatus at the same time.

 

 

 

 

 

However, a "busy" response is given if the zoom or focus lens is being driven .

 

 

 

 

 

 

 

( Refer to the ZCONTDRV command and FCONTDRV command.

 

 

 

 

 

 

(2) Step control for the zoom lens can be exercised using the ZSTEPDRV command.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example

> RANGE ZSTEPDRV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< r:ZSTEPDRV=I, WIDE, TELE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Commands

 

SX50

SX6

 

SX60

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supported

01.00**

01.01**

 

01.01**

01.01**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

×

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When a command is not supported, "e:000A INVALID_PARAMETER" is returned.

 

 

 

 

 

 

Supported Command States

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Power supply

 

 

 

 

 

 

Input

 

 

 

 

 

 

Mode

Remarks

 

OFF

ON

PM

D-RGB

A-RGB1

A-RGB2

Comp

Video

 

S-Video

D-Video

SCART

None

Remote

 

Local

 

SX50

 

 

 

 

 

SX6

×

×

 

 

 

 

×

 

SX60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If a state is not supported, "INVALID_MODE" or "NOT_POWER_SUPPLIED" is returned with the Err response. *When the power supply state is in the process of switching, an "i:BUSY" reply may be sent.