User Command Specifications

9. Details of command POWER

1

Commands

POWER

 

 

Mode

Control

Setting

Reference

Function

This controls the power supply

 

 

 

 

 

 

 

Format

 

POWER<Parameter:ID>

 

 

 

 

 

 

 

 

 

Parameter

 

 

 

 

 

 

 

 

 

 

Parameter

Meaning

 

 

 

 

 

 

 

ON

Power ON

 

 

 

 

 

 

 

OFF

Power OFF

 

 

 

 

ID

 

The parameters which can be controlled at any given point in time can be obtained

 

 

 

using the RANGE command.

 

 

For details, refer to the RANGE command.

 

 

 

Response "i:OK" is returned if the parameter was set properly.

 

 

For all other responses, refer to "Error List."

 

Description This performs ON/OFF control of the power supply.

 

-1 This command is identical to pressing the POWER button on the remote control or main unit.

 

-2 Provided that the remote mode is established, the command can be executed in any projector

 

 

status.

 

 

 

 

 

 

 

 

However, zoom or focus lens drive stops if the zoom or focus lens is being driven.

 

 

(Refer to the ZCONTDRV command and FCONTDRV command.)

 

-3 After sending this command, use GET POWER to obtain the power supply state at regular

 

 

intervals, and check that it is in the controlled state (off or on).

 

-4 The table below shows the POWER command responses according to the power supply state.

POWER Command Responses by

Power Supply State

Commands

POWER ON

POWER OFF

 

Status

 

 

 

Off

 

Off -> lighted

 

Lamp on

 

Lighted -> off

 

Lighted -> standby

○: i:OK

In standby

○ ※

Standby -> lighted

△: i:BUSY

-5 The current power supply status can be referenced using the applicable GET command. For details, refer to the GET command.

Example Control

>POWER ON

<i:OK

Reference

>GET POWER or ?POWER < g:POWER=OFF

Acquisition of parameters which can be set

> RANGE POWER

<r:POWER=I,ON,OFF

*Commands are indicated by ">", and responses are indicated by "<".

Commands

SX50

SX6

SX60

X600

 

 

 

 

supported

01.00**

01.01**

01.01**

01.01**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Supported Command States

Model

Power

 

 

 

 

Input

 

 

 

 

Mode

Remarks

 

OFF

ON

PM

D-RGB

A-RGB1

A-RGB2

Comp

Video

S-Video

D-Video

SCART

None

Remote

Local

 

SX50

×

 

SX6

×

 

SX60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* "i:BUSY" may be returned if the power status is being switched.

PAGE 16

Page 24
Image 24
Canon X600, SX60 specifications Format Power Parameter :ID, Example Control, Power on