Canon X600, SX60 specifications Version revision history

Models: SX60 X600

1 190
Download 190 pages 0 b
Page 2
Image 2

User Command Specifications

Version revision history

I. Version revision history

Numerical

Date

Description of revised version

value

 

 

Where revised

01.0100/01

01.0100/02

01.0100/03

01.0100/04

01.0100/05

2005.11.01

2005.11.10

2005.11.14

2005.12.05

2005.12.27

Version first created.

 

Version number of User Commands changed to "01.0100."

Entire document

Listing of the parameters for each command changed to the listing obtained by the "RANGE" command.

Entire document

"Character interval timeout" in communication specifications changed from 10ms to 5 seconds (timeout

PAGE 2

between CR and LF is 10ms).

 

"GUID" in "User Command System" changed to "GUIDE."

PAGE 8

"GUID" in "Command List" changed to "GUIDE.

PAGE 12

Condition added to "RC/MAIN commands" as a condition for returning from power management standby

PAGE 11

in "Power Management Mode."

 

"AUTOSETEXE" command changed from a "setting" command to a "control" command.

PAGE 12, 17

"Auto screen color correction" of the "AUTOSETEXE" command changed to "automatic screen color

PAGE 17

correction."

 

Error response information added in "Response" of the "AUTOSETEXE" command.

PAGE 17

Condition for disabling "INPUT" execution added to "Description" of the "AUTOSETEXE" command.

PAGE 17

The fact that the screen color correction (WB) is to be adjusted after executing automatic screen color

PAGE 17

correction added to "Description" of the "AUTOSETEXE" command.

 

Support for the D-Video input of the SX6/SX60/X600 in the "Supported (command) states" of the

PAGE 24

"HPIX/VPIX" commands revised.

 

Support for the SX6/SX60/X600 in the "Supported (command) states" of the "ASPECT" command revised.

PAGE 26

The fact that settings are to be performed by the system for the SX6/SX60/X600 added to the description

PAGE 37

of the "WBRGB" command.

 

Support for no signals of the SX50 in the "Supported (command) states" of the "VKS/HKS" commands

PAGE 48

revised.

 

"ZSTEPDRV," "ZCONTDRV," "FSTEPDRV" and "FCONTDRV" commands changed from "control"

PAGE 12,6568

commands to "setting" commands.

 

"GET ERR" removed from "(4) Zoom/focus stop commands" in the "ZCONTDRV" and "FCONTDRV"

PAGE 66,68

commands.

 

Commands for responding normally while drive is maintained added in the "ZCONTDRV" and

PAGE 66,68

"FCONTDRV" commands.

 

"GUID" parameter of "GET" command changed to "GUIDE."

PAGE 72,115

"NOSHOWSTATUS" parameter of "GET" command changed to "NOSHOWSTATE."

PAGE 72,118

Support for the D-Video of the SX6/SX60/X600 in the "Supported (command) states" of the "GET

PAGE 80

HPIX/VPIX" commands revised.

PAGE 82

Action to be taken when D-Video, SCART or none is applicable in the "Supported (command) states" of

the "GET ASPECT" command revised.

PAGE 101

Action to be taken when no SX50 signals are provided in the "Supported (command) states" of the "GET

VKS/HKS" commands revised.

 

Description of the version information obtained by "GET COMVER" command added.

PAGE 125

"GUID" parameter of "RANGE" command changed to "GUIDE."

PAGE 126,170

Support for the local mode of the SX6/SX60/X600 in the "Supported (command) states" of the "RANGE

PAGE 128

POWER" command revised.

 

Support for the local mode of the SX6/SX60/X600 in the "Supported (command) states" of the "RANGE

PAGE 131

INPUT" command revised.

 

Support for the D-Video of the SX6/SX60/X600 in the "Supported (command) states" of the "RANGE

PAGE 135

HPIX/VPIX" commands revised.

 

Action to be taken when D-Video, SCART or none is applicable in the "Supported (command) states" of

PAGE 137

the "RANGE ASPECT" command revised.

 

Action to be taken when no SX50 signals are provided in the "Supported (command) states" of the

PAGE 156

"RANGE VKS/HKS" commands revised.

 

Pressing of POWER button added to the conditions for clearing BLANK of the "BLANK" command.

PAGE 18

Listing of the parameters in "Example" of the "RANGE ZSTEPDRV" command revised.

PAGE 173

Listing of the parameters in "Example" of the "RANGE ZCONTDRV" command revised.

PAGE 174

"INPUT_NOT_FOUND" added to "Error List."

PAGE 177

The fact that the guide display is not cleared in "Remote mode" added.

PAGE 14

Support for the SX6/SX60/X600 in the "Supported (command) states" of the "ASPECT" command revised.

PAGE 26

Operation performed when "GUIDE-OFF" is received in "Remote mode" added.

PAGE 62

Processing to be undertaken for the "GET MODE" command in cases where zoom or focus lens drive is

PAGE 73

underway deleted.

 

Processing to be undertaken for the "GET POWER" command in cases where zoom or focus lens drive is

PAGE 74

underway deleted.

 

Support for the local mode of the SX6/SX60/X600 in the "Supported (command) states" of the "GET

PAGE 103

MUTE" command revised.

 

Processing to be undertaken for the "GET LAMPCOUNTER" command in cases where zoom or focus

PAGE 121

lens drive is underway deleted.

 

Processing to be undertaken for the "GET PRODCODE" command in cases where zoom or focus lens

PAGE 123

drive is underway deleted.

 

Processing to be undertaken for the "GET ROMVER" command in cases where zoom or focus lens drive

PAGE 124

is underway deleted.

 

Processing to be undertaken for the "GET COMVER" command in cases where zoom or focus lens drive

PAGE 125

is underway deleted.

 

In "2. Communication System," "Time out" described separately for SX50 and SX6/SX60/X600.

PAGE 2

Statuses of SX6/SX60/X600, TRUE and A-RGB1 in the "Supported (command) states" of the "ASPECT"

PAGE 26

command changed from "x" to "O."

 

The fact that the response to the "ZCONTDRV" command in cases where zoom drive is underway is

PAGE 66

"unconditionally" i:BUSY clearly indicated.

 

The fact that the response to the "FCONTDRV" command in cases where focus drive is underway is

PAGE 68

"unconditionally" i:BUSY clearly indicated.

 

"BUSY (FOCUS)" and "BUSY (ZOOM)" priority levels raised.

PAGE 177

 

 

Page 2
Image 2
Canon X600, SX60 specifications Version revision history