iDP-562 User’s Manual
CITIZEN 23
6.2 Setting the Dip Switch
IDP562CNL / CN has Dip Switch with which you can select the followings to meet your computer’s function.
Selection of “CR” and “LF” code function.
Please refer to the table below.
DSW-1 DSW-2 DSW-3
CR and LF code When CR code comes
are valid function. immediately after full When the buffer is blank.
*OFF CR code is selected buffer printing
by the DSW-2
and 3. *OFF CR code is void *OFF CR code is valid
ON CR code is valid ON CR code is void
CR code is ignored When LF code comes
LF code is valid. immediately after full When the buffer is blank.
ON LF code is selected buffer printing
by the DSW-2
and 3. *OFF LF code is void *OFF LF code is valid
ON LF code is valid ON LF code is void
It is recommended to set the DIP switches in accordance with your host’s output DATA format.
DATA Form DSW-1 DSW-2 DSW-3
DATA + CR OFF OFF OFF
DATA + LF
DATA + CR + LF ON OFF OFF
DATA + LF + CR
USA GERMANY FRANCE UK
DSW-4 *OFF OFF ON ON
Foreign character
Selection DSW-5 *OFF ON OFF ON
DSW-6
¯Not for use
DSW-10
NOTE: *Marks are a “Factory Setting”