Problem

Cause

Measure

 

 

 

Power does not turn on

Fuse is blown.

Replace with a fuse of the same

(or no sound is produced)

 

amperage as the old fuse.

 

 

 

 

Connections are improper.

Read the attached “Installation/Wire

 

 

Connection Guide” once again and

 

 

wire properly.

 

 

 

Sound quality is poor.

Playback head is dirty.

Use a cleaning tape, etc. to clean the

 

 

head.

 

 

 

No sound while unit can

Power ANT lead is shorted

Turn the unit off, first.

be operated.

to the ground.

Remove all connecting wires from the

 

 

power ANT lead, and turn the unit on,

 

 

then re-connect a wire one by one to

 

 

the power ANT lead.

 

 

When sound is muted again, check

 

 

the unit with a wire connected last.

 

 

 

7.ERROR DISPLAYS

To protect the system, this unit has been equipped with self diagnostic functions. If a fault arises, a warning is issued by various error displays. Follow the corrective measures and remove the fault.

Error Display

Corrective Measure

 

 

Er 2

This error display indicates that a fault has arisen in the mechanism of the

source unit or CD changer (for example, the disc cannot be changed or

ejected).

 

Check the source unit and CD changer.

 

 

Er 3

This error display indicates that the pickup focus is off because of a

scratched disc or some other factor during source unit or CD changer play.

Check the compact disc.

 

 

Er 6

This indicates that the CD’s TOC (table of contents) cannot be read, for

example because the selected disc is upside-down.

 

 

 