Troubleshooting

Page 1 of 2

[Table of Contents] [Previous Page] [Next Page]

16. TROUBLESHOOTING

In case a problem occurs, first check wiring connector connections.

PROBLEMS

When the main power is not on, the machine is not activated.

PTV screen is blackened and the fluorescent lamp does not light up.

CAUSE

The power is not ON.

Incorrect power source/voltage.

AC Unit fuse blown off due to instantaneous overcurrent.

Power supply unit fuse blown off due to instantaneous overcurrent.

COUNTERMEASURES

Firmly insert the plug into the outlet.

Make sure that the power supply/voltage are correct.

First remove the cause of overcurrent, then replace the fuse (see Sec. 6).

514-5036-15000 AC100~120V

FUSE 6.4 ØX 30 AREA 15000mA 125V

514-5037-8000 AC220~240V

FUSE 6.4 ØX 30 AREA 8000rnA 250V

First remove the cause of overcurrent, then replace the fuse.

514-5036-10000

FUSE 6.4 ØX 30 10000mA 125V

PTV screen is all blue.

Defective connections in

between each board.

 

The color of image on

Connector connections are

PTV screen is incorrect.

defective.

 

Incorrect monitor adjustment.

PTV screen has a color

Affected by the periphery, such

deviation.

as other machines, location

 

building's steel frames, etc.

Sound is not emitted.

Sound volume adjustment is not

 

correct.

 

Malfunctioning of sound BD

 

and memory.

Control panel and pedal

V. R. position deviated, or V. R

not operable satisfactorily.

malfunctioning.

Make sure of correct connections in between each board.

Check to see if connector connections of RGB and SYNC are correct.

Make appropriate adjustments (see Sec. 13).

Make convergence adjustments (see Sec. 13).

Change installation direction/position. Move the other machines which cause the problem.

Adjust the SWITCH UNIT's sound adjustment volume (control) (see Sec. 8).

Perform SOUND TEST (see Sec. 8).

Adjust or replace the V. R. (see Sec. 9 & 10).

 

ADJUST GEAR's engagement is Adjust the engagement of ADJUST

 

not correct.

GEAR (see Sec. 9 & 10).

SHIFT LEVER doesn't

Switch position deviated, or

Adjust or replace the

509-5566

SW MICRO

operate satisfactorily.

switch malfunctioning.

Switch (see Sec. 11).

TYPE

 

 

 

Steering Wheel reaction

 

First turn the power off and then turn it

http://www.sauservice.com/manuals/Daytona%20Folder/DDhtml/DD45.html7/12/2005

Page 44
Image 44
Sega DLX owner manual Troubleshooting, Problems, Cause, Countermeasures