Maintenance

5.Make sure the valve on the recovery drain hose is clean. Tightly close the valve.

6.Make sure the brush/pad is in position and installed correctly.

7.Make sure brush housing and skirts are in position on the brush head.

8.Check the installation of the squeegee and squeegee hose.

9.Make sure the solution drain / level indicator hose is secure on the storage mount on the rear of the machine.

Do These Procedures When You End Your Work

1.Drain the solution tank (Figure 31) and the recovery tank (Figure 32). To drain the tanks , follow this procedure:

a.Press the red "OFF" button or turn key switch counterclockwise to "OFF" position ("L" model only).

b.Remove the drain hose from the back of the machine.

c.Put the end of the hose over a drain or bucket.

d.Recovery Tank:

1.) Turn the valve housing to the left (See Figure 33).

2.) To open the valve completely, turn the housing fully to the left. Pull the housing off of the valve (Figure 34).

e.Solution Tank:

When hose is lowered below water level, water will flow.

2.Flush the tanks. To flush the tanks, put clean water in the tank through the opening on top of the tank.

3.If a tank or drain hose has an obstruction, use a pressure water hose to flush the tank or hose. Put the water hose into the drain hose.

4.Leave the tanks and the recovery drain valve open to dry in the air.

5.Check the squeegee blade. Use a cloth to clean the squeegee blade. If the squeegee blade is damaged or worn, turn or replace the blade.

6.Check and clean the recovery lid gasket. Use a mild cleaning solution and rinse the parts in clean water.

Figure 31

Figure 32

Figure 33

Figure 34

Clarke® Operator's Manual -FOCUS S17/L17 and S20/L20