EN
Maintenance
7.On machines with cylindrical brush head, the debris tray needs to be emptied regularly to prevent overflow. To remove the debris tray from the machine follow this procedure (See Figure 35).
a.Go to the left side of the machine, to the rear of the cylindrical brush head.
b.Grab the end of the tray with the left hand and the center of the tray with the right hand.
c.Lift center of tray with right hand and slide tray out with left hand.
d.Empty tray and clean before sliding tray back in. Make sure upper and lower slides are engaged.
Figure 35
Check the batteries and if necessary add distilled water after charging. The correct level is within 1/4 inch (1/2 cm) of the bottom of the tube in each cell.
CAUTION: Tap water may contain contaminants that will damage batteries. Batteries must be refilled with DISTILLED WATER ONLY.
WARNING: Lead acid batteries generate gases which can cause an explosion. NO SMOKING. Always wear eye protection and protective clothing when working near batteries.
Use a clean cloth and wipe the surface of the machine.
Charge the batteries. See the instructions in the section of this book called “How To Charge The Batteries”.
Maintenance Procedures To Be Done Every Week:
WARNING: Maintenance and repairs must be done by authorized personnel only. Always empty the solution tank and the recovery tank before doing any maintenance. Keep all fasteners tight.
WARNING: Always wear eye protection and protective clothing when working near batteries. Do not put tools or other metal objects across the battery terminals or the tops of the batteries.
CAUTION: To prevent damage to the machine, and discharge across the tops of the batteries, do not fill the batteries above the bottom of the tube in each cell. Wipe any acid from the machine or the tops of the batteries. Do not add acid to battery after installation.
Page | Clarke® Operator's Manual |