Cobalt Networks 8310(-C), 8321(-C) Cable Connections, Without Fan Kit, Fan Kit Installed

Models: 8321(-C) 8310(-C)

1 48
Download 48 pages 36.92 Kb
Page 16
Image 16

Notice

For reliable performance, it is recommended that the frame door not be opened for longer than 5 minutes when using the Cooling Fan Module option on frames loaded with more than 40 Watt.

Without Fan Kit:

Empty Space

8310

Max. 40 Watt

Empty Space

Fan Kit Installed:

8310-C

Max. 120W Module Power

8310-C

Max. 120W Module Power

8310-C

Max. 120W Module Power

Figure 1. Cooling Fan Module Frame Stacking Options

Cable Connections

Power Supply Inputs

SMPTE Alarm BNC

Reference Connectors

RossBUS Connector

Ethernet Connector

Figure 2. Frame Cable Connectors

Power Cable Connection

Use the following procedure to connect the power cable:

1.Connect the supplied power cable’s three prong male connector to an AC outlet.

2.Connect the cable’s female IEC connector to the frame socket marked PSU 1.

3.If the Redundant Power Supply option is installed, repeat step 1 and 2, plugging the second IEC connector into PSU 2.