Cobalt Networks 9006 owner manual Rear Module Installation Optional, Page 10 of

Models: 9006

1 18
Download 18 pages 62.29 Kb
Page 10
Image 10
Rear Module Installation (Optional)

Rear Module Installation (Optional)

If you are installing the card in a 8310-C-BNC or 8310-BNC frame (one with a 100 BNC rear module installed across the entire back plane), skip this section.

If you are installing the card into a slot with no rear module, you should have ordered and received a RM-9006-A Rear Module with your card. You will need to install it in your 8310 frame before you can connect cables.

Use the following steps to install the RM-9006-A in an 8310 openGearTM frame:

1.Refer to the openGearTM 8310 frame Owner’s Manual, to ensure that the frame is properly installed according to instructions.

2.On the rear of the 8310, locate the card frame slot.

3.As shown in Figure 2, seat the bottom of the RM-9006-A in the seating slot at the base of the frame’s back plane.

Figure 2. Rear Module Installation

4.Align the top hole of the RM-9006-A with the screw hole on the top edge of the 8310 back plane.

5.Using a Phillips driver and the supplied screw, fasten the RM-9006-A panel to the 8310 back plane. Do not over tighten.

This completes the procedure for installing the RM-9006-A in an 8310 openGearTM frame.

Page 10 of 18

9006 Owner’s Manual (V 1.0)

Page 10
Image 10
Cobalt Networks 9006 owner manual Rear Module Installation Optional, Page 10 of